Hansegård Jøger, Urheim Stig, Lunde Ketil, Rabben Stein Inge
Department of Informatics, University of Oslo, NO-0317 Oslo, Norway.
IEEE Trans Med Imaging. 2007 Oct;26(10):1391-400. doi: 10.1109/TMI.2007.900692.
This paper presents multiview and multiframe active appearance models (AAMs) for left ventricular segmentation in triplane echocardiograms. We describe a general way of integrating local edge detector based segmentation algorithms into the AAM framework. The feasibility of this approach is evaluated by comparing an AAM constrained by a dynamic programming (DP) based snake with an unconstrained AAM, and an AAM constrained by manually defined landmarks. A leave-one-out validation scheme was used for training and testing of the methods. Evaluation was done in 36 patients suffering from various heart diseases, using manually determined volumes and ejection fractions (EF) as reference. The segmentation was initialized by manual selection of the mitral annulus and apex in three imaging planes. The differences, in volume, between manual segmentation and the best automatic method (DP-constrained AAM) were -3.1 +/- 20 ml (mean +/-SD) at end-diastole and 0.61 +/- 13 ml at end-systole. The difference in EF was -1.3 +/- 6.3%, comparable to the interobserver variability. We show that 1) constraining the model to manually defined landmarks improves volume and EF estimates compared to unconstrained AAMs, 2) further improvement is achieved using a DP-constrained AAM, and 3) segmentation in triplane echocardiograms gives higher accuracy than single plane data.
本文提出了用于三平面超声心动图中左心室分割的多视图和多帧主动外观模型(AAM)。我们描述了一种将基于局部边缘检测器的分割算法集成到AAM框架中的通用方法。通过比较基于动态规划(DP)的蛇形模型约束的AAM与无约束的AAM以及由手动定义地标约束的AAM,评估了该方法的可行性。采用留一法验证方案对这些方法进行训练和测试。在36例患有各种心脏病的患者中进行评估,使用手动确定的容积和射血分数(EF)作为参考。通过在三个成像平面中手动选择二尖瓣环和心尖来初始化分割。在舒张末期,手动分割与最佳自动方法(DP约束的AAM)之间的容积差异为-3.1±20 ml(平均值±标准差),在收缩末期为0.61±13 ml。EF的差异为-1.3±6.3%,与观察者间的变异性相当。我们表明:1)与无约束的AAM相比,将模型约束到手动定义的地标可改善容积和EF估计;2)使用DP约束的AAM可进一步改善;3)三平面超声心动图中的分割比单平面数据具有更高的准确性。