Samanidou Victoria F, Nisyriou Styliani A, Papadoyannis Ioannis N
Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.
J Sep Sci. 2007 Dec;30(18):3193-201. doi: 10.1002/jssc.200700199.
A high-performance liquid chromatographic method was developed for the determination of five penicillins: penicillin G (PENG), penicillin V (PENV), oxacillin (OX), cloxacillin (CLO), and dicloxacillin (DICLO), in bovine muscle. Samples were macerated with a mixture of H(2)O/CH(3)CN (1:1) and purified using RP-8 Adsorbex SPE cartridges after centrifugation, with mean recovery from spiked samples higher than 89%. The separation of the examined penicillins was achieved on an analytical column, an Inertsil C8 5 microm, 250x4 mm(2), at ambient temperature. The mobile phase consisted of 0.1% TFA/ACN 50:50 v/v delivered isocratically at a flow rate of 1.1 mL/min. Analytes were monitored at 240 nm. The procedure was validated according to the European Union Decision 2002/657/EC by means of selectivity, stability, decision limit, detection capability, accuracy, and precision. Method's LOQ values achieved were 54 microg/kg for PENG and DICLO, 46 microg/kg for PENV, 16 microg/kg for OX, and 43 microg/kg for DICLO. The detection capabilities (CC(beta)) were 73.6 microg/kg for PENG, 29.1 microg/kg for PENV, 350.6 microg/kg for OX, 379.9 microg/kg for CLO, and 355.8 microg/kg for DICLO. The method was applied to various samples from the local market. Two penicillins were identified by photodiode array (PDA) detection and quantified.
建立了一种高效液相色谱法,用于测定牛肌肉中五种青霉素:青霉素G(PENG)、青霉素V(PENV)、苯唑西林(OX)、氯唑西林(CLO)和双氯西林(DICLO)。样品用H₂O/CH₃CN(1:1)混合物研磨,离心后使用RP - 8 Adsorbex固相萃取柱纯化,加标样品的平均回收率高于89%。在所考察的青霉素在Inertsil C8 5μm、250×4 mm²分析柱上于室温下实现分离。流动相由0.1%三氟乙酸/乙腈(50:50 v/v)等度洗脱,流速为1.1 mL/min。在240 nm处监测分析物。该方法根据欧盟第2002/657/EC号决定,通过选择性、稳定性、决策限、检测能力、准确性和精密度进行了验证。该方法获得的最低定量限(LOQ)值为:PENG和DICLO为54μg/kg,PENV为46μg/kg,OX为16μg/kg,CLO为43μg/kg。检测能力(CC(β))为:PENG为73.6μg/kg,PENV为29.1μg/kg,OX为350.6μg/kg,CLO为379.9μg/kg,DICLO为355.8μg/kg。该方法应用于当地市场的各种样品。通过光电二极管阵列(PDA)检测鉴定并定量了两种青霉素。