Injac Rade, Djordjevic-Milic Vukosava, Srdjenovic Branislava
Faculty of Pharmacy, Department of Pharmaceutical Biology, University of Ljubljana, Askerceva 7, 1000 Ljubljana, Slovenia.
J Chromatogr Sci. 2007 Oct;45(9):623-8. doi: 10.1093/chromsci/45.9.623.
A high-performance liquid chromatography (HPLC) method for the quantitation of doxycycline in bulk, tablets, and capsules after storage at -20, 5, 25, 40, 50, 60, and 70 degrees C, has been developed and validated. The samples are eluted from a micro-Bondapak C8 column (4.6x150-mm, i.d., 5-microm particle size) at 27 degrees C, with a mobile phase of acetonitrile-water-THF (29.5:70:0.5, v/v/v), adjusted to pH 2.5 with 1.0M HCl. The flow rate is 1.0 mL/min and detection by UV is at 350 nm. The stability of doxycycline in bulk and in pharmaceuticals is checked over 90 days. Doxycycline shows thermo-degradation after exposure to high temperature; tablets are more stable than capsules. The shelf lives (t90%) are determined to be 1.00, 2.84, and 5.26 years in bulk, capsules, and tablets, respectively, at 25 degrees C. Metacycline and 6-epidoxycyline are identified as degradation products at high temperatures. Amounts of doxycycline, metacycline, and 6-epidoxycycline in all samples are determined by HPLC, and the results compare with those from micellar electrokinetic capillary chromatography. After 90 days, metacycline and 6-epidoxycyline are almost equal in test samples from standard bulk form, tablets, and capsules. It is 27.8+/-0.3%, 13.7+/-0.1%, and 18.8+/-0.2%, respectively.
已开发并验证了一种高效液相色谱(HPLC)方法,用于定量分析在-20、5、25、40、50、60和70摄氏度下储存后的多西环素原料药、片剂和胶囊中的含量。样品在27摄氏度下从微Bondapak C8柱(内径4.6x150-mm,粒径5微米)上洗脱,流动相为乙腈-水-四氢呋喃(29.5:70:0.5,v/v/v),用1.0M盐酸调节至pH 2.5。流速为1.0 mL/分钟,通过紫外检测,检测波长为350 nm。在90天内检查多西环素原料药和药物制剂的稳定性。多西环素在高温下会发生热降解;片剂比胶囊更稳定。在25摄氏度下,原料药、胶囊和片剂的有效期(t90%)分别确定为1.00、2.84和5.26年。在高温下,美他环素和6-表氧环素被鉴定为降解产物。通过HPLC测定所有样品中多西环素、美他环素和6-表氧环素的含量,并将结果与胶束电动毛细管色谱法的结果进行比较。90天后,标准原料药、片剂和胶囊的测试样品中美他环素和6-表氧环素的含量几乎相等。分别为27.8±0.3%、13.7±0.1%和18.8±0.2%。