Myers R E, Stånge L, Joelsson I, Huzell B, Wussow C
Acta Obstet Gynecol Scand. 1977;56(3):195-203. doi: 10.3109/00016347709162120.
Catheters were placed into assorted arteries and veins of 8 anaesthetized pregnant monkeys and their fetuses. Oxygen-sensitive electrodes were also inserted subcutaneously into 3 of the 8 fetuses. Periodic samples of maternal and fetal blood were analyzed for PO2, PCO2 and pH. Oxygen administration to the mothers reliably increased the PO2 of blood taken from the fetal carotid artery and less constantly augmented the PO2 of blood withdrawn from the femoral artery and vein. During 5-6 hours of study the oxygen tension of fetal blood samples of all animals progressively declined. However, the most marked declines in PO2 values at all fetal sites were regularly observed at those times as--or after--the mothers emerged from anaesthesia. At these times also the magnitudes of the increases in fetal blood PO2 brought about by administering oxygen to the mothers diminished markedly and in parallel at all sample sites. The closely similar magnitudes of these various reductions at all fetal sample sties indicate that the basic mechanisms leading to decreased oxygen delivery lie outside the fetuses and are most likely due to decreased maternal blood flow to the uterus because of increased maternal sympathetic stimulation. These reductions in oxygen delivery to the fetus are all regularly reversed by reanasthetizing the mothers. The studies carried out with oxygen-sensitive electrodes demonstrate that administering oxygen to the mothers regularly increases oxygen tension of fetal tissues but after a 50 sec delay.
将导管插入8只麻醉的怀孕猴子及其胎儿的各种动脉和静脉中。还将氧敏感电极皮下插入8只胎儿中的3只。定期分析母体和胎儿血液样本的氧分压(PO2)、二氧化碳分压(PCO2)和pH值。给母体吸氧确实增加了从胎儿颈动脉采集的血液的PO2,而从股动脉和静脉采集的血液的PO2增加则不太稳定。在5至6小时的研究过程中,所有动物的胎儿血液样本的氧张力逐渐下降。然而,在母体从麻醉中苏醒时或苏醒后,所有胎儿部位的PO2值下降最为明显。在这些时候,给母体吸氧所导致的胎儿血液PO2的增加幅度在所有采样部位也明显且平行地减小。在所有胎儿采样部位,这些不同程度降低的幅度非常相似,这表明导致氧输送减少的基本机制存在于胎儿之外,很可能是由于母体交感神经刺激增加导致母体子宫血流量减少。通过再次麻醉母体,这些向胎儿的氧输送减少情况都会定期得到逆转。使用氧敏感电极进行的研究表明,给母体吸氧会使胎儿组织的氧张力有规律地增加,但会有50秒的延迟。