Suppr超能文献

健康犬猫不同换能器部位所获多普勒衍生主动脉流速的比较。

Comparison of Doppler-derived aortic velocities obtained from various transducer sites in healthy dogs and cats.

作者信息

Riesen Sabine C, Doherr Marcus G, Lombard Christophe W

机构信息

Division of Small Animal Internal Medicine, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Berne, PO Box 8466, 3001 Berne, Switzerland.

出版信息

Vet Radiol Ultrasound. 2007 Nov-Dec;48(6):570-3. doi: 10.1111/j.1740-8261.2007.00299.x.

Abstract

In normal dogs and dogs with subaortic stenosis, it is known that the subcostal transducer site provides higher left ventricular ejection velocities than does the left apical site. We hypothesized that aortic flow velocities could also be obtained from the right parasternal long-axis view, optimized for the placement of the Doppler cursor as parallel as possible into the aortic root. In 15 healthy dogs and 13 healthy cats, high-pulsed repetition frequency Doppler flow velocity measurements in the proximal aorta were performed using two-dimensional echocardiographic guidance. The mean [ +/- standard error of the mean (SEM)] peak aortic flow velocities in healthy dogs were as follows: subcostal site 1.46 +/- 0.05 m/s; apical site 1.12 +/- 0.06 m/s; right parasternal long-axis site 1.09 +/- 0.05 m/s. In healthy cats, the following peak aortic flow velocities were observed: apical site 0.87 +/- 0.03m/s; right parasternal long-axis site 0.87 +/- 0.03 m/s. Aortic flow velocities obtained from the subcostal site were significantly higher in healthy dogs than those obtained from the left apical and right parasternal long-axis site (P< 0.001). There was no statistical difference between the peak aortic flow velocities obtained from right parasternal long-axis and left apical transducer position in all groups. We conclude therefore that right parasternal long-axis and left apical-derived aortic flow velocities are similar and may be used interchangeably in healthy dogs and cats.

摘要

已知在正常犬以及患有主动脉瓣下狭窄的犬中,肋下换能器位置所测得的左心室射血速度高于心尖左部位置。我们推测,通过右胸骨旁长轴视图也可获取主动脉血流速度,该视图需将多普勒光标尽可能平行地放置于主动脉根部进行优化。在15只健康犬和13只健康猫中,在二维超声心动图引导下对主动脉近端进行了高脉冲重复频率多普勒血流速度测量。健康犬的平均[±平均标准误差(SEM)]主动脉血流峰值速度如下:肋下位置为1.46±0.05米/秒;心尖位置为1.12±0.06米/秒;右胸骨旁长轴位置为1.09±0.05米/秒。在健康猫中,观察到的主动脉血流峰值速度如下:心尖位置为0.87±0.03米/秒;右胸骨旁长轴位置为0.87±0.03米/秒。健康犬从肋下位置获得的主动脉血流速度显著高于从心尖左部和右胸骨旁长轴位置获得的速度(P<0.001)。在所有组中,从右胸骨旁长轴和心尖左部换能器位置获得的主动脉血流峰值速度之间无统计学差异。因此,我们得出结论,右胸骨旁长轴和心尖左部所测得的主动脉血流速度相似,在健康犬和猫中可相互替代使用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验