Bergamaschi R, Romani A, Versino M, Callieco R, Delnevo L, Cosi V
Istituto Neurologico C. Mondino, Università di Pavia.
Boll Soc Ital Biol Sper. 1991 Jun;67(6):593-9.
Somatosensory Evoked Potentials by stimulation of the trigeminal nerve (TSEPs) were recorded from 30 healthy subjects (15 males, 15 females; mean age: 45.2 years; range: 21-66 years) in order to assess normative data for clinical purposes. To elicit the TSEPs, electrical square pulses (duration: 0.1 msec; frequency: 3.3 Hz; intensity: 4-6 mA) were delivered by bipolar skin electrodes (cathode over the foramen mentale and anode on the middle of the chin, stimulating the trigeminal third branch). TSEPs were obtained from C3-Fpz and C4-Fpz by twice averaging 1000 responses. Time base was 100 msec; bandpass filter setting was 5-1500 Hz. In our normal subjects the TSEPs were composed of several components (N1, P1, N2, P2 and N3); the components, with the exception of N3, were always bilaterally detectable. Statistical analysis (repeated measures analysis of variance) demonstrated a dependence of TSEP latencies on sex; it did not demonstrate an analogous dependence on either side of stimulation or age. Finally, we propose some guidelines for the evaluation of TSEPs: consider N1, P1, N2 and P2 waves, base the judgement of normality on latencies rather on amplitudes, use differing normative data according to sex.
为了评估临床应用的标准数据,对30名健康受试者(15名男性,15名女性;平均年龄:45.2岁;范围:21 - 66岁)进行三叉神经刺激体感诱发电位(TSEP)记录。为引出TSEP,通过双极皮肤电极(阴极置于颏孔上方,阳极置于下巴中部,刺激三叉神经第三支)施加电方波脉冲(持续时间:0.1毫秒;频率:3.3赫兹;强度:4 - 6毫安)。通过对1000次反应进行两次平均,从C3 - Fpz和C4 - Fpz获得TSEP。时基为100毫秒;带通滤波器设置为5 - 1500赫兹。在我们的正常受试者中,TSEP由几个成分组成(N1、P1、N2、P2和N3);除N3外,这些成分总是双侧可检测到。统计分析(重复测量方差分析)表明TSEP潜伏期与性别有关;未表明其对刺激侧或年龄有类似的依赖性。最后,我们提出了一些评估TSEP的指导原则:考虑N1、P1、N2和P2波,根据潜伏期而非波幅判断是否正常,根据性别使用不同的标准数据。