Development of a standardized method for motion testing in pulse oximeters.

作者信息

Shang Allan B, Kozikowski Raymond T, Winslow Andrew W, Weininger Sandy

机构信息

From the *Department of Anesthesiology, Duke University Medical Center; †The Fitzpatrick Institute for Photonics, Duke University; ‡Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina; and §The Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MO.

出版信息

Anesth Analg. 2007 Dec;105(6 Suppl):S66-S77. doi: 10.1213/01.ane.0000278132.12257.cd.

DOI:10.1213/01.ane.0000278132.12257.cd
PMID:18048902
Abstract

BACKGROUND

Pulse oximeter performance in the presence of motion varies among devices and manufacturers because of variations in hardware, software, testing, and calibration. Compounding these differences is a lack of uniform characterization of motion, and the consequential effects of motion upon the wide range of normal and abnormal human physiology. Traditional motion testing attempts to standardize motion into a reproducible form by using a mechanical jig to produce passive motion of a known amplitude and frequency. This type of motion challenge fails to account for the physiologic changes induced by active movement.

METHODS

We postulate that a more appropriate method for testing the performance of pulse oximeters in the presence of motion is to create a feedback control loop between the device and the test subject, providing a reproducible, actively created, and controlled motion test suitable for standardized testing among manufacturers. It is hoped that relying on a signal as seen from the oximeter's perspective will enable the creation of a sensitive and reproducible test method capable of separating those oximeters that can reject motion artifact from those that cannot.

RESULTS

Preliminary results have concentrated on building the tools and clinical protocols needed to evaluate this method. Some basic observations are reported, but insufficient numbers of experienced subjects precludes rigorous conclusions.

CONCLUSION

We have set the stage for a feasibility demonstration using a novel form of testing. With sufficient subjects and proper statistical evaluation, a robust test method for assessing the performance of pulse oximeters in the presence of motion may be at hand.

摘要

相似文献

1
Development of a standardized method for motion testing in pulse oximeters.
Anesth Analg. 2007 Dec;105(6 Suppl):S66-S77. doi: 10.1213/01.ane.0000278132.12257.cd.
2
The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia.运动伪影和低灌注对新一代脉搏血氧仪在低氧血症志愿者中的性能影响。
Respir Care. 2002 Jan;47(1):48-60.
3
The Sounds of Desaturation: A Survey of Commercial Pulse Oximeter Sonifications.血氧饱和度下降的声音:商业脉搏血氧仪声音提示功能的调查
Anesth Analg. 2016 May;122(5):1395-403. doi: 10.1213/ANE.0000000000001240.
4
Maximizing the laboratory setting for testing devices and understanding statistical output in pulse oximetry.优化检测设备的实验室环境并理解脉搏血氧饱和度测定中的统计输出结果。
Anesth Analg. 2007 Dec;105(6 Suppl):S85-S94. doi: 10.1213/01.ane.0000268495.35207.ab.
5
The effect of motion on pulse oximetry and its clinical significance.运动对脉搏血氧饱和度测定的影响及其临床意义。
Anesth Analg. 2007 Dec;105(6 Suppl):S78-S84. doi: 10.1213/01.ane.0000278134.47777.a5.
6
Effects of motion on the performance of pulse oximeters in volunteers.运动对志愿者脉搏血氧仪性能的影响。
Anesthesiology. 1996 Oct;85(4):774-81. doi: 10.1097/00000542-199610000-00012.
7
A prototype device for standardized calibration of pulse oximeters II.用于脉搏血氧仪标准化校准的原型设备II。
J Clin Monit Comput. 2002 Apr-May;17(3-4):203-9. doi: 10.1023/a:1020795307742.
8
Design and validation of a pulse oximeter calibrator.脉搏血氧仪校准仪的设计与验证
Anesth Analg. 2002 Jan;94(1 Suppl):S8-12.
9
A prototype device for standardized calibration of pulse oximeters.一种用于脉搏血氧仪标准化校准的原型设备。
J Clin Monit Comput. 2000;16(3):161-9. doi: 10.1023/a:1009931527538.
10
Oxygen targeting in preterm infants using the Masimo SET Radical pulse oximeter.使用 Masimo SET Radical 脉搏血氧仪对早产儿进行氧目标靶向治疗。
Arch Dis Child Fetal Neonatal Ed. 2011 Nov;96(6):F429-33. doi: 10.1136/adc.2010.206011. Epub 2011 Mar 6.

引用本文的文献

1
Accuracy of pulse oximeter perfusion index in thoracic epidural anesthesia under basal general anesthesia.基础全身麻醉下胸部硬膜外麻醉中脉搏血氧饱和度仪灌注指数的准确性
Int J Clin Exp Med. 2014 Jul 15;7(7):1728-34. eCollection 2014.