Suppr超能文献

辅助步行器:步行的能量消耗

Parawalker: energy cost of walking.

作者信息

Banta J V, Bell K J, Muik E A, Fezio J

机构信息

Dept. of Orthopaedics, Newington Children's Hospital, Connecticut 06111.

出版信息

Eur J Pediatr Surg. 1991 Dec;1 Suppl 1:7-10. doi: 10.1055/s-2008-1042527.

Abstract

Relative oxygen cost (ml/kg/m) was compared in five paraplegic subjects (4 children, 1 adult) while wearing a reciprocating gait orthosis (RGO) and Parawalker. An Oxylog was used to record oxygen consumption while the subjects ambulated during steady state. Although all of the subjects trained and used the orthoses for varying amounts of time, the trend from these data shows that the Parawalker enables a more energy efficient gait. On the average the oxygen cost while using the Parawalker was 27% less compared to the RGO. The reductions in oxygen cost ranged from 12 to 42%. Following this trend of greater efficiency, the subjects ambulated 33% faster (on the average) with the Parawalker than with the RGO. These preliminary results indicate that the Parawalker appears to be a more efficient orthosis for level ambulation in the paraplegic population.

摘要

对五名截瘫患者(4名儿童,1名成人)在穿戴往复式步态矫形器(RGO)和Parawalker时的相对氧气消耗(毫升/千克/米)进行了比较。在受试者稳态行走期间,使用Oxylog记录氧气消耗量。尽管所有受试者训练和使用矫形器的时间各不相同,但这些数据的趋势表明,Parawalker能实现更节能的步态。平均而言,使用Parawalker时的氧气消耗比使用RGO时少27%。氧气消耗的减少幅度在12%至42%之间。遵循这种更高效率的趋势,受试者使用Parawalker行走的速度(平均)比使用RGO快33%。这些初步结果表明,对于截瘫人群的平地行走,Parawalker似乎是一种更高效的矫形器。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验