Seiler Gabriela S, Ziemer Lisa S, Schultz Susan, Lee William M F, Sehgal Chandra M
Department of Clinical Studies, Philadelphia, School of Veterinary Medicine, University of Pennsylvania, 3900 Delancey Street, Philadelphia, PA 19104, USA.
Cancer Imaging. 2007 Dec 17;7(1):216-23. doi: 10.1102/1470-7330.2007.0031.
Many factors affect the sensitivity and reliability of tumor vasculature assessment at the small doses of contrast agent necessary for imaging mice. In this study we investigate the dose-response relationship of ultrasound contrast agent for a minimal exposure power Doppler technique (minexPD) in a murine melanoma model. K1735 murine melanomas grown in 25 C3H/HeN mice were imaged by power Doppler ultrasound using different doses of contrast agents, Optison(R) and Definity(R). Six mice were treated with an antivascular agent, combretastatin A4-phosphate (CA4P), and imaged before and after treatment. The color-weighted fractional area (CWFA) of the peak-enhanced image was measured to assess tumor perfusion on a relative scale of 0 to 100. CWFA increased logarithmically with dose (R(2)=0.97). Treatment with CA4P resulted in pronounced reduction in tumor perfusion 2 h after contrast injection, but perfusion recovered in the tumor periphery after 2 days. CWFA was significantly different between pre- and post-treatment for all doses at 2 h and 2 days (p < 0.05, respectively). There was no significant difference detectable between the two contrast agents, Optison(R) and Definity(R) (p = 0.46). In vivo tumor enhancement in mice increases as logarithmic function with dose. Although the extent of enhancement is dose dependent, the difference between pre- and post-therapy enhancement is relatively unchanged and uniform at varying doses. The two contrast agents tested in this study performed equally well. These results suggest that quantitative contrast-enhanced power Doppler imaging is an effective method for monitoring therapy response of tumors in mice.
在对小鼠进行成像所需的小剂量造影剂条件下,许多因素会影响肿瘤血管系统评估的敏感性和可靠性。在本研究中,我们在小鼠黑色素瘤模型中研究了超声造影剂对于最小暴露功率多普勒技术(minexPD)的剂量反应关系。使用不同剂量的造影剂Optison®和Definity®,通过功率多普勒超声对25只C3H/HeN小鼠体内生长的K1735小鼠黑色素瘤进行成像。六只小鼠接受了抗血管生成药物磷酸羟基喜树碱(CA4P)治疗,并在治疗前后进行成像。测量峰值增强图像的颜色加权分数面积(CWFA),以在0至100的相对尺度上评估肿瘤灌注。CWFA随剂量呈对数增加(R² = 0.97)。注射造影剂2小时后,CA4P治疗导致肿瘤灌注显著降低,但2天后肿瘤周边的灌注恢复。在2小时和2天时,所有剂量下治疗前后的CWFA均有显著差异(分别为p < 0.05)。两种造影剂Optison®和Definity®之间未检测到显著差异(p = 0.46)。小鼠体内肿瘤增强随剂量呈对数函数增加。尽管增强程度取决于剂量,但在不同剂量下,治疗前后增强的差异相对不变且一致。本研究中测试的两种造影剂表现同样良好。这些结果表明,定量对比增强功率多普勒成像对于监测小鼠肿瘤的治疗反应是一种有效的方法。