在人黑色素瘤异种移植模型中比较超声造影与血管生成免疫组化标志物:初步结果。

Comparing contrast-enhanced ultrasound to immunohistochemical markers of angiogenesis in a human melanoma xenograft model: preliminary results.

作者信息

Forsberg Flemming, Dicker Adam P, Thakur Mattew L, Rawool Nandkumar M, Liu Ji-Bin, Shi William T, Nazarian Levon N

机构信息

Department of Radiology, Division of Ultrasound, Thomas Jefferson University, Main Building, Suite 763J, 132 South 10th Street, Philadelphia, PA 19107, USA.

出版信息

Ultrasound Med Biol. 2002 Apr;28(4):445-51. doi: 10.1016/s0301-5629(02)00482-9.

Abstract

This study compared contrast-enhanced ultrasound (US) measures of tumor neovascularity with molecular markers of angiogenesis in a human melanoma xenograft model. A total of 14 mice were implanted with a human melanoma cell line (WM-9) in the thigh. After 2 to 3 weeks, a tumor, approximately 12 mm in diameter, developed. The US contrast agent Optison (Mallinckrodt, St. Louis, MO) was injected in a tail vein (dose: 0.4 to 0.6 mL/kg). Power Doppler and pulse-inversion harmonic imaging (HI) were performed with an Elegra scanner (Siemens Medical Systems, Issaquah, WA) and a 7.5 MHz linear array. Frame-rates of 30 Hz and 0.5 Hz (intermittent imaging) were used for pulse-inversion HI. After surgical removal, specimens were sectioned in the same planes as the US images. Immunohistochemical stains for endothelial cells (CD31), vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF) and cyclooxygenase-2 (COX-2) were performed. Two observers graded the stains (for intensity and percent area), and two other observers graded the US imaging modes (for fractional tumor neovascularity) on the same scale from 0 to 3. Of the 14 mice, 4 failed for technical reasons (i.e., n = 10). Linear regressions indicated statistically significant correlations between percent area stained with COX-2 and power Doppler (r = -0.789; p < 0.01), as well as intermittent pulse-inversion HI (r = -0.795; p < 0.05). There was a trend toward significance between percent area stained with VEGF and intermittent pulse-inversion HI (r = -0.720; 0.05 < p < 0.10). No other comparisons were significant. In conclusion, contrast-enhanced US measures of tumor neovascularity in a human melanoma xenograft model appear to provide a noninvasive marker of angiogenesis corresponding to expression of COX-2. However, the sample size of this study is small and, until further studies have been conducted, these conclusions are preliminary.

摘要

本研究在人黑色素瘤异种移植模型中,比较了肿瘤新生血管的超声造影(US)测量结果与血管生成的分子标志物。总共14只小鼠在大腿植入人黑色素瘤细胞系(WM - 9)。2至3周后,形成直径约12毫米的肿瘤。超声造影剂Optison(马林克罗德特公司,密苏里州圣路易斯)经尾静脉注射(剂量:0.4至0.6毫升/千克)。使用Elegra扫描仪(西门子医疗系统公司,华盛顿州伊萨夸)和7.5兆赫线性阵列进行能量多普勒和脉冲反转谐波成像(HI)。脉冲反转HI采用30赫兹和0.5赫兹(间歇成像)的帧率。手术切除后,将标本切成与超声图像相同的平面。进行内皮细胞(CD31)、血管内皮生长因子(VEGF)、碱性成纤维细胞生长因子(bFGF)和环氧合酶 - 2(COX - 2)的免疫组织化学染色。两名观察者对染色进行评分(强度和面积百分比),另外两名观察者以相同的0至3评分标准对超声成像模式(肿瘤新生血管分数)进行评分。14只小鼠中,4只因技术原因失败(即n = 10)。线性回归表明,COX - 2染色面积百分比与能量多普勒之间存在统计学显著相关性(r = -0.789;p < 0.01),与间歇脉冲反转HI之间也存在相关性(r = -0.795;p < 0.05)。VEGF染色面积百分比与间歇脉冲反转HI之间有显著趋势(r = -0.720;0.05 < p < 0.10)。其他比较均无显著性。总之,在人黑色素瘤异种移植模型中,肿瘤新生血管的超声造影测量似乎提供了一种与COX - 2表达相对应的血管生成的非侵入性标志物。然而,本研究的样本量较小,在进行进一步研究之前,这些结论是初步的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验