Vilches Manuel, García-Pareja Salvador, Guerrero Rafael, Anguiano Marta, Lallena Antonio M
Servicio de Física y Protección Radiológica, Hospital Regional Universitario Virgen de las Nieves, Granada, Spain.
Radiother Oncol. 2008 Jan;86(1):104-8. doi: 10.1016/j.radonc.2007.11.026. Epub 2007 Dec 20.
Results obtained from Monte Carlo simulations of the transport of electrons in thin slabs of dense material media and air slabs with different widths are analyzed. Various general purpose Monte Carlo codes have been used: PENELOPE, GEANT3, GEANT4, EGSNRC, MCNPX. Non-negligible differences between the angular and radial distributions after the slabs have been found. The effects of these differences on the depth doses measured in water are also discussed.