Suppr超能文献

坦桑尼亚达累斯萨拉姆肺结核痰涂片显微镜检查诊断的质量

The quality of sputum smear microscopy diagnosis of pulmonary tuberculosis in Dar es Salaam, Tanzania.

作者信息

Mfinanga G S, Ngadaya E, Mtandu R, Mutayoba B, Basra D, Kimaro G, Chonde T M, Ngowi P, Mfaume S, Kilale A M, Egwaga S, Kitua A Y

机构信息

National Institute for Medical Research, Muhimbili Medical Research Centre, P.O. Box 3436, Dar es Salaam, Tanzania.

出版信息

Tanzan Health Res Bull. 2007 Sep;9(3):164-8. doi: 10.4314/thrb.v9i3.14323.

Abstract

This study was carried out to determine the rate of agreement or disagreement of microscopy reading and culture positivity rate among smear positixe and negative specimens between peripheral tuberculosis diagnostic centres (PDCs) and Central Reference luberculosis laboratory (CTRL). In this study 13 PDCs in Dar es Salaam, Tanzania were involved. Lot Quality Assurance Sampling (LQAS) method was used to collect 222 sputum smear slides. A total of 190 morning sputum specimens with corresponding slides were selected for culture. First readings were done by technicians at PDCs and thereafter selected slides and specimens were sent to CTRL for re-examination and culture. Culture results were used as a gold standard. Of 222 slides selected, 214 were suitable for re-examination. Percentage of agreement of smear reading between PDCs and CTRL was 42.9% and 100% for positive and negative slides, respectively. Measure of agreement (Kappa statistic) was 0.5, indicating moderate agreement. Of 190 samples cultured, percentage of agreement between smear reading from PDCs and CTRL was 37% and 88.9% for smear positive and negative slides, respectively. Kappa statistic was 0.3 indicating poor-fair agreements. Comparison of smear reading from PDCs with culture showed sensitivity of 36.9% and specificity of 88.9%. Comparison of smear readings from CTRL with culture results showed sensitivity of 95.6% and specificity of 98.6%. In conclusion there was inadequate performance in diagnosis of TB using smear microscopy among peripheral diagnostic centres in Dar es Salaam. This calls for immediate and rigorous measures to improve the quality of smear microscopy. It is therefore important to strengthen the capacity of laboratory personnel in smear microscopy techniques through supportive supervision and training.

摘要

本研究旨在确定外周结核病诊断中心(PDC)与中央参考结核病实验室(CTRL)之间,涂片阳性和阴性标本的显微镜检查结果与培养阳性率的一致或不一致率。本研究涉及坦桑尼亚达累斯萨拉姆的13个PDC。采用批量质量保证抽样(LQAS)方法收集了222份痰涂片玻片。总共选择了190份早晨痰液标本及相应玻片进行培养。首先由PDC的技术人员进行初读,然后将选定的玻片和标本送至CTRL进行复查和培养。培养结果用作金标准。在选定的222份玻片中,214份适合复查。PDC与CTRL之间涂片读数的阳性和阴性玻片一致率分别为42.9%和100%。一致性度量(kappa统计量)为0.5,表明一致性中等。在190份培养样本中,PDC与CTRL涂片读数的涂片阳性和阴性玻片一致率分别为37%和88.9%。kappa统计量为0.3,表明一致性较差。PDC涂片读数与培养结果的比较显示敏感性为36.9%,特异性为88.9%。CTRL涂片读数与培养结果的比较显示敏感性为95.6%,特异性为98.6%。总之,达累斯萨拉姆外周诊断中心使用涂片显微镜检查诊断结核病的表现不佳。这就需要立即采取严格措施来提高涂片显微镜检查的质量。因此,通过支持性监督和培训来加强实验室人员在涂片显微镜检查技术方面的能力非常重要。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验