Muris Joris, Kleverlaan Cornelis J, Feilzer Albert J, Rustemeyer Thomas
Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Louwesweg 1, 1066 EA Amsterdam, The Netherlands.
Contact Dermatitis. 2008 Jan;58(1):42-6. doi: 10.1111/j.1600-0536.2007.01259.x.
In the last decades, palladium is widely used in dentistry. Allergic reactions to palladium are rarely diagnosed with patch testing, even when positive results would be expected. Palladium tends to cross-react with nickel, which should give rise to more positive reactions to palladium dichloride (standard test salt).
The aim of the study was to test whether or not mono-nuclear sodium tetrachloropalladate (Na(2)[PdCl(4)]) in petrolatum is a better test salt for diagnosing palladium allergy. Positive reactions to the investigated test salt are compared not only with PdCl(2(aq.)), but also to NiSO(4(aq.)) and NiSO(4(pet.)).
PATIENTS/METHODS: Concentration series of Na(2)[PdCl(4)] were carried out. 164 consecutive patients were patch tested.
3% of Na(2)PdCl(4) was found to be the highest non-irritative concentration. The results show (n = 164) that Na(2)[PdCl(4)] covers all reactions to PdCl(2) (1.8%) and provokes more positive reactions (14%). From the 164 patients, 18.3% reacted positively to at least 1 of the nickel salts.
The sensitivity of patch testing with Na(2)[PdCl(4)] is increased compared with the PdCl(2) salt. Therefore, it can be concluded that Na(2)[PdCl(4)] is to be a better test salt for diagnosing palladium allergy with patch testing.
在过去几十年中,钯在牙科领域被广泛使用。即使预期会得到阳性结果,通过斑贴试验对钯过敏的反应也很少被诊断出来。钯往往会与镍发生交叉反应,这应该会导致对二氯化钯(标准试验盐)产生更多阳性反应。
本研究的目的是测试凡士林基质中的四氯钯酸钠单核(Na(2)[PdCl(4)])是否是诊断钯过敏的更好试验盐。不仅将对所研究试验盐的阳性反应与PdCl(2(aq.))进行比较,还与NiSO(4(aq.))和NiSO(4(pet.))进行比较。
患者/方法:进行了Na(2)[PdCl(4)]的浓度系列实验。对164名连续患者进行了斑贴试验。
发现3%的Na(2)PdCl(4)是最高的无刺激性浓度。结果显示(n = 164),Na(2)[PdCl(4)]涵盖了对PdCl(2)的所有反应(1.8%),并引发了更多阳性反应(14%)。在这164名患者中,18.3%对至少一种镍盐呈阳性反应。
与PdCl(2)盐相比,用Na(2)[PdCl(4)]进行斑贴试验的敏感性有所提高。因此,可以得出结论,Na(2)[PdCl(4)]是用于斑贴试验诊断钯过敏的更好试验盐。