Suppr超能文献

[根据ISO 9360: 2000标准对四种热湿交换器过滤器进行的加湿评估]

[Humidification assessment of four heat and moisture exchanger filters according to ISO 9360: 2000 standard].

作者信息

Lannoy D, Décaudin B, Resibois J-P, Barrier F, Wierre L, Horrent S, Batt C, Moulront S, Odou P

机构信息

Service pharmacie, centre hospitalier, 130, avenue Louis-Herbeaux, B.P. 6367, 59385 Dunkerque cedex 1, France.

出版信息

Ann Fr Anesth Reanim. 2008 Feb;27(2):148-53. doi: 10.1016/j.annfar.2007.11.012. Epub 2007 Dec 31.

Abstract

OBJECTIVE

This work consisted of the assessment of humidification parameters and flow resistance for different heat and moisture exchanger filters (HMEF) used in intensive care unit. Four electrostatic HMEF were assessed: Hygrobac S (Tyco); Humidvent compact S (Teleflex); Hygrovent S/HME (Medisize-Dräger); Clear-Therm+HMEF (Intersurgical).

MATERIAL AND METHODS

Humidification parameters (loss of water weight, average absolute moisture [AAM], absolute variation of moisture) have been evaluated on a bench-test in conformity with the ISO 9360: 2000 standard, for 24h with the following ventilatory settings: tidal volume at 500 ml, respiratory rate at 15 c/min, and inspiration/expiration ratio at 1:1. The flow resistance of HMEFs assessed using the pressure drop method was measured before and after 24h of humidification for three increasing air flows of 30, 60, and 90 l/min.

RESULTS

All the HMEFs allowed satisfactory level of humidification exceeding 30 mgH(2)O/l. The less powerful remained the Clear-Therm. Concerning HMEFs flow resistance, results showed a pressure drop slightly more important for the Hygrobac S filter as compared with other filters.

CONCLUSION

This test showed differences between the HMEFs for both humidification and resistance parameters. When compared to the new version of the standards, HMEFs demonstrated their reliability. However, evolution of humidification and flow resistance characteristics over 24h showed a structural degradation of HMEFs, limiting their use over a longer period.

摘要

目的

本研究旨在评估重症监护病房中使用的不同热湿交换过滤器(HMEF)的加湿参数和流动阻力。评估了四种静电HMEF:Hygrobac S(泰科医疗);Humidvent compact S(泰利福);Hygrovent S/HME(美迪赛-德尔格);Clear-Therm+HMEF(英特舒医疗)。

材料与方法

根据ISO 9360:2000标准,在台架试验中评估加湿参数(失水量、平均绝对湿度[AAM]、湿度绝对变化),在以下通气设置下进行24小时试验:潮气量500毫升,呼吸频率15次/分钟,吸呼比1:1。使用压降法评估HMEF的流动阻力,在加湿24小时前后,对30、60和90升/分钟三种递增气流进行测量。

结果

所有HMEF的加湿水平均令人满意,超过30毫克H₂O/升。加湿能力最弱的是Clear-Therm。关于HMEF的流动阻力,结果显示,与其他过滤器相比,Hygrobac S过滤器的压降略高。

结论

该测试表明,HMEF在加湿和阻力参数方面存在差异。与新版标准相比,HMEF证明了其可靠性。然而,24小时内加湿和流动阻力特性的变化表明HMEF存在结构退化,限制了其长期使用。