[Dose and image quality in intraoral radiography].

作者信息

Hjardemaal O

机构信息

Statens Institut for Strålehygiejne, København.

出版信息

Tandlaegebladet. 1991 Nov;95(16):748-51.

PMID:1816648
Abstract

The technique factors when performing intraoral X-ray exposures must be selected in such a way that sufficient diagnostic information is obtained at a reasonable patient dose. The Danish National Institute of Radiation Hygiene has performed a study comprising 32 dental X-ray sets. The mean value of the skin dose for a maxillary molar was 9.6 mGy and the value for the dental colleges 7.0 mGy. For a mandibular incisor the corresponding doses were 7.7 mGy and 3.6 mGy. After the conclusion of the mentioned study it has been part of the institute's inspection procedure for dental X-ray sets to measure patient skin doses. 243 measurements were performed and the mean value of the entrance skin dose was 6.5 mGy and the dose interval was 0.7-57 mGy. All doses are normalised to speed class D film. At 16% of the inspected sets films of speed class E were used. The remainder used class D films. The spread in doses cannot be explained by variation in equipment parameters alone but is to a high degree due to a combination of inappropriate film processing and exposure time. Interviews with staff in dental clinics confirm that films are frequently processed until the desired density is obtained by visual estimation. It is shown that the skin dose when using film of speed class D can be kept below 7 mGy for a mandibular incisor. Concluding is stated that film processing shall be performed in accordance with specifications from the manufacturer of the developer. Film of speed class E must be used. Finally must the exposure time be graduated according to the object exposed.

摘要

相似文献

1
[Dose and image quality in intraoral radiography].
Tandlaegebladet. 1991 Nov;95(16):748-51.
2
Image quality assessment and radiation doses in intraoral radiography.口腔内放射摄影中的图像质量评估与辐射剂量
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2001 Mar;91(3):362-8. doi: 10.1067/moe.2001.111940.
3
Dose reduction of intraoral dental radiography in Spain.西班牙口腔内牙片摄影的剂量降低
Dentomaxillofac Radiol. 2006 Jul;35(4):295-8. doi: 10.1259/dmfr/26405790.
4
Patient radiation dose management in dental facilities according to the X-ray focal distance and the image receptor type.
Dentomaxillofac Radiol. 2007 Jul;36(5):282-4. doi: 10.1259/dmfr/67494525.
5
Absorbed doses from intraoral radiography with special emphasis on collimator dimensions.口腔内放射摄影的吸收剂量,特别强调准直器尺寸。
Swed Dent J. 1986;10(1-2):59-71.
6
Mail survey of dental radiographic techniques and radiation doses in Greece.希腊牙科放射技术与辐射剂量的邮件调查。
Dentomaxillofac Radiol. 1998 Nov;27(6):321-8. doi: 10.1038/sj/dmfr/4600385.
7
Quality control and diagnostic reference levels in intraoral dental radiographic facilities.口腔牙科X线摄影设备的质量控制与诊断参考水平
Dentomaxillofac Radiol. 2005 Sep;34(5):304-7. doi: 10.1259/dmfr/38802780.
8
Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography.牙科放射摄影中用于诊断参考水平的剂量面积乘积测量及患者剂量分析。
Radiat Prot Dosimetry. 2012 Jul;150(4):523-31. doi: 10.1093/rpd/ncr439. Epub 2011 Dec 5.
9
Radiation dose as a factor in the choice of routine pre-operative dental radiographs.辐射剂量作为常规术前牙科X光片选择的一个因素。
East Afr Med J. 1993 May;70(5):297-301.
10
Diagnostic reference levels in intraoral dental radiography in Korea.韩国口腔牙科X线摄影的诊断参考水平。
Imaging Sci Dent. 2012 Dec;42(4):237-42. doi: 10.5624/isd.2012.42.4.237. Epub 2012 Dec 23.