Suppr超能文献

"Drop-and-Sip" fluid handling technique for the reagent-release capillary (RRC)-based capillary-assembled microchip (CAs-CHIP): sample delivery optimization and reagent release behavior in RRC.

作者信息

Henares Terence G, Mizutani Fumio, Sekizawa Ryuichi, Hisamoto Hideaki

机构信息

Graduate School of Material Science, University of Hyogo, 3-2-1 Kouto, Kamigori, Ako,Hyogo 678-1297, Japan.

出版信息

Anal Sci. 2008 Jan;24(1):127-32. doi: 10.2116/analsci.24.127.

Abstract

The experimental conditions of the sample delivery inside the reagent-release capillary-based capillary-assembled microchip (RRC-based CAs-CHIP) were optimized and the reagent release procedure in the RRC is discussed. Recently, our group introduced the basic concept of the "drop-and-sip" fluid handling technique (Anal. Chem., 2007, 79, 908). A microliter volume of sample solution is dropped on the inlet hole and is sipped into another hole, producing a sample plug flow in the main poly(dimethyl siloxane) (PDMS) channel, concurrently filling each sensing capillary that faces the main PDMS channel. However, the detailed evaluation of the successful sample delivery condition and the reagent release behavior in the RRC has not been fully discussed. Under our experimental conditions, ca. 0.6 - 2.4 s of sample plug-RRC contact time allowed the successful sample introduction into the RRC by capillary force without any reagent leakage or disturbance of the sample plug flow. On the other hand, reagent release behavior inside the RRC is governed by both convective and diffusive mass transport, which leads to a faster mixing time of the sample with reagents immobilized inside the RRC compared to that expected from the simple diffusion alone.

摘要

相似文献

3
4
Nanoliter capillary electrochromatography columns based on collocated monolithic support structures molded in poly(dimethyl siloxane).
Electrophoresis. 2001 Oct;22(17):3736-43. doi: 10.1002/1522-2683(200109)22:17<3736::AID-ELPS3736>3.0.CO;2-Y.
5
Single-drop analysis of various proteases in a cancer cell lysate using a capillary-assembled microchip.
Anal Bioanal Chem. 2008 Aug;391(7):2507-12. doi: 10.1007/s00216-008-2105-x. Epub 2008 Apr 23.
6
Rotatable reagent cartridge for high-performance microvalve system on a centrifugal microfluidic device.
Anal Chem. 2013 Jul 16;85(14):6587-92. doi: 10.1021/ac400667e. Epub 2013 Jun 26.
9
Integration of valving and sensing on a capillary-assembled microchip.
Anal Chem. 2005 Apr 1;77(7):2266-71. doi: 10.1021/ac0484528.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验