Suppr超能文献

Acrylamido polyvinyl alcohol microspheres for uterine artery embolization: 12-month clinical and MR imaging results.

作者信息

Kroencke Thomas J, Scheurig Christian, Lampmann Leo E H, Boekkooi Peter F, Kissner Lutz, Kluner Claudia, Weichert Wilko, Hamm Bernd, Lohle Paul N M

机构信息

Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.

出版信息

J Vasc Interv Radiol. 2008 Jan;19(1):47-57. doi: 10.1016/j.jvir.2007.08.019.

Abstract

PURPOSE

To report the 12-month clinical and magnetic resonance (MR) imaging results of an ongoing two-center registry involving acrylamido polyvinyl alcohol (PVA) microspheres for uterine artery embolization (UAE) for leiomyomas.

MATERIALS AND METHODS

A total of 69 patients underwent UAE with 500-700-microm, 700-900-microm, and 900-1,200-mum acrylamido PVA microspheres (BeadBlock). Thirty-three patients underwent UAE with a limited embolization (protocol A) and 36 patients underwent UAE with stasis as the angiographic endpoint (protocol B). Primary objectives were clinical efficacy measured by a leiomyoma-specific quality of life (QOL) questionnaire and infarction rate of leiomyomas on early contrast agent-enhanced MR imaging. Secondary objectives were in-hospital complications, patient satisfaction, and frequency of clinical failure.

RESULTS

Bilateral embolization was technically successful in 68 of 69 patients. A significant decrease (P < .001) in symptom severity and increase in health-related QOL was observed at 3 and 12 months with no significant differences between embolization protocols. However, contrast agent-enhanced MR imaging showed a significantly lower rate of completely infarcted leiomyomas in protocol A compared with protocol B (P < .05). Early clinical failures in patients treated according to protocol A were caused by incomplete tumor infarction. Minor complications occurred in five of 69 patients. Patient satisfaction was similar between protocols.

CONCLUSIONS

Acrylamido PVA microspheres are a clinically effective and safe embolic agent for UAE. The use of 500-700-microm spheres and a limited embolization results in an unacceptably high rate of failed tumor infarction. Superior imaging results and fewer repeat interventions can be achieved with use of 700-900-microm spheres and stasis as the angiographic endpoint.