Sputum cytology is a non-invasive test for evaluating lung cancer. But, its sensitivity is yet lower than other tests. ThinPrep (TP) is an automated cytopreparatory method that has mucolytic and hemolysing effects. We compared 955 sputum specimens that were prepared by both TP and conventional preparation (CP). The nuclear details were more preserved on the TP slides, while the obscuring materials were more eliminated on the TP slides as compared with the CP. The cytologic rates of TP were 2.7% unsatisfactory, 4.7% normal, 81.0% benign, 2.4% suspicious, and 9.1% malignancy. The rates of CP were 7.9% unsatisfactory, 1.6% normal, 84.8% benign, 1.8% suspicious, and 4.0% malignancy. The false negative rates, relative to the histologic data for 352 cases which the tissue diagnosis was available, were 49.6% (TP) and 69.4% (CP). Sputum cytology using the TP method improves the diagnostic accuracy for evaluating lung cancer by reducing the unsatisfactory and false-negative rates.
痰细胞学检查是一种用于评估肺癌的非侵入性检查。但是,其敏感性仍低于其他检查。ThinPrep(TP)是一种具有黏液溶解和溶血作用的自动化细胞制备方法。我们比较了955份采用TP和传统制备方法(CP)制备的痰标本。与CP相比,TP玻片上的细胞核细节保存得更好,同时TP玻片上的遮盖物被更多地清除。TP的细胞学检查结果为:不满意率2.7%,正常率4.7%,良性率81.0%,可疑率2.4%,恶性率9.1%。CP的结果为:不满意率7.9%,正常率1.6%,良性率84.8%,可疑率1.8%,恶性率4.0%。相对于352例有组织诊断结果的组织学数据,假阴性率分别为49.6%(TP)和69.4%(CP)。采用TP方法的痰细胞学检查通过降低不满意率和假阴性率提高了评估肺癌的诊断准确性。