强度反射系数:一种用超声研究血液后向散射特性的补充方法。

The intensity reflection coefficient: a complementary method for investigating blood backscattering properties with ultrasound.

作者信息

Amararene Amar, Cloutier Guy

机构信息

Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montreal, Quebec, Canada.

出版信息

Clin Hemorheol Microcirc. 2008;38(3):189-200.

Abstract

Parametric imaging of backscatter indices is an active field of research in ultrasound (US) tissue characterization. The US intensity reflection coefficient (IRC) is introduced to characterize porcine blood in a Couette shear flow system. US properties of red blood cells (RBCs) were investigated at shear rates of 5 s(-1) and 500 s(-1) for hematocrits ranging from 0 to 54%. The IRC was determined and compared to the integrated backscatter power (IBP) calculated between 8 MHz and 12 MHz. The frequency dependence of both parameters was also explored using their spectral slopes determined in the same frequency bandwidth. The experimental results showed that the IRC is a mirror function of the IBP and their spectral slopes had similar behavior. At a shear rate of 500 s(-1), selected to disaggregate RBCs, the IRC exhibited a bi-modal variation with a minimum at 23% hematocrit. The minimum was less pronounced and moved down to 13-17% hematocrits in the case of a shear rate of 5 s(-1) that promoted aggregation. The IBP presented a sharp peak at 25% hematocrit for the high shear-rate value, while a plateau appeared after 13% hematocrit in the case of the low shear rate. Furthermore, the transition from lower to higher shear rate was accompanied by a diminution in the level of both indices. In the frequency domain, the spectral slope of the backscatter power presented a Rayleigh scattering behavior (value around 4) for all hematocrits at a shear rate of 500 s(-1). It dropped to a value of 2 beyond 13% hematocrit when the shear rate was decreased to 5 s(-1). At a shear rate of 500 s(-1), the spectral slope of the IRC was constant and close to 3.8 below 28% hematocrit and decreased at higher hematocrits. At 5 s(-1), it was constant (between 3.7 and 3.9) for hematocrits lower than 17% and then decreased. This study showed the potential of the intensity reflection coefficient to investigate the RBC aggregation phenomenon. An advantage of IRC is its easy computation.

摘要

背向散射指数的参数成像在超声(US)组织表征中是一个活跃的研究领域。引入超声强度反射系数(IRC)来表征库埃特剪切流系统中的猪血。在剪切速率为5 s⁻¹和500 s⁻¹的条件下,研究了血细胞比容范围为0%至54%时红细胞(RBC)的超声特性。测定了IRC,并与在8 MHz至12 MHz之间计算的积分背向散射功率(IBP)进行比较。还利用在相同频率带宽内确定的光谱斜率探讨了这两个参数的频率依赖性。实验结果表明,IRC是IBP的镜像函数,它们的光谱斜率具有相似的行为。在选择用于使RBC解聚的500 s⁻¹的剪切速率下,IRC呈现双峰变化,在血细胞比容为23%时出现最小值。在促进聚集的5 s⁻¹的剪切速率情况下,最小值不太明显,并且下移至13% - 17%的血细胞比容。对于高剪切速率值,IBP在血细胞比容为25%时出现一个尖锐峰值,而在低剪切速率情况下,在血细胞比容超过13%后出现一个平台期。此外,从较低剪切速率到较高剪切速率的转变伴随着两个指数水平的降低。在频域中,对于500 s⁻¹的剪切速率,所有血细胞比容下背向散射功率的光谱斜率呈现瑞利散射行为(值约为4)。当剪切速率降低到5 s⁻¹时,在血细胞比容超过13%后它下降到2的值。在500 s⁻¹的剪切速率下,低于28%血细胞比容时,IRC的光谱斜率是恒定的且接近3.8,在较高血细胞比容时降低。在5 s⁻¹时,低于17%的血细胞比容时它是恒定的(在3.7和3.9之间),然后降低。这项研究显示了强度反射系数在研究RBC聚集现象方面的潜力。IRC的一个优点是其易于计算。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验