Suppr超能文献

Combination of high-performance liquid chromatography and radioimmunoassay for the measurement of urodilatin and alpha-hANP in the urine of healthy males.

作者信息

Solc J, Bauer K, Timnik A, Solcova A, Döhlemann C, Strom T M, Weil J

机构信息

Dept. of Pediatrics, University of Munich, FRG.

出版信息

Life Sci. 1991;48(25):2451-6. doi: 10.1016/0024-3205(91)90380-t.

Abstract

Urodilatin (ANP-(95-126)), a natriuretic peptide in urine, and alpha-hANP (ANP-(99-126)) are crossreactive in the radioimmunoassay of alpha-hANP (ANP-RIA). We therefore developed a method to separate physiological amounts of urodilatin and alpha-hANP in urine by high-performance liquid chromatography (HPLC) followed by ANP-RIA of the separated fractions. We studied urine samples of 10 healthy adult males with a plasma alpha-hANP level of 41 +/- 21 pg/ml (mean +/- SD) and a total urinary ANP-RIA reactivity of 40 +/- 21 pg/ml. In all urine samples we found three peaks of ANP-RIA reactivity, the first one coeluting with synthetic urodilatin, the second one with the retention time of alpha-hANP and a late eluting ANP-RIA-reactive peak, possibly containing degradation products. The ratio of urodilatin/alpha-hANP was 0.77 +/- 0.17.