Amano Yasuo, Takahama Katsuya, Kumita Shinichiro
Department of Radiology, Nippon Medical School, Tokyo, Japan.
J Magn Reson Imaging. 2008 Mar;27(3):504-9. doi: 10.1002/jmri.21256.
To assess the usefulness of non-contrast-enhanced MR angiography using cardiac and navigator-gated magnetization-prepared three-dimensional (3D) steady-state free precession (SSFP) imaging for the diagnosis of diseases of the thoracic aorta.
Twenty-two patients with diseases of the thoracic aorta were examined using a 1.5 Tesla unit. Non-contrast-enhanced MR angiography was done using parasagittal 3D SSFP combined with cardiac-gating and k-space weighted navigator-gating techniques, using T2-prepared and fat-suppression pulses. Imaging quality and the diagnostic capability of this technique were compared with the imaging quality of 2D SSFP or contrast-enhanced 3D MR angiography and with final diagnoses.
Non-contrast-enhanced 3D MR angiography provided signal-to-noise and contrast-to-noise ratios of the thoracic aorta comparable to non-contrast-enhanced 2D or contrast-enhanced 3D MR angiography (P > 0.17). This imaging technique gave accurate diagnoses in 19 of the 22 patients.
Non-contrast-enhanced MR angiography using cardiac and navigator-gated magnetization-prepared 3D SSFP technique was useful for the diagnosis of diseases of the thoracic aorta.
评估采用心脏和导航门控磁化准备三维(3D)稳态自由进动(SSFP)成像的非增强磁共振血管造影术在胸主动脉疾病诊断中的实用性。
使用1.5特斯拉设备对22例胸主动脉疾病患者进行检查。采用矢状旁3D SSFP结合心脏门控和k空间加权导航门控技术,使用T2准备和脂肪抑制脉冲进行非增强磁共振血管造影。将该技术的成像质量和诊断能力与二维SSFP或增强3D磁共振血管造影的成像质量以及最终诊断结果进行比较。
非增强3D磁共振血管造影提供的胸主动脉信噪比和对比噪声比与非增强2D或增强3D磁共振血管造影相当(P>0.17)。该成像技术在22例患者中的19例中做出了准确诊断。
采用心脏和导航门控磁化准备3D SSFP技术的非增强磁共振血管造影术对胸主动脉疾病的诊断有用。