Suppr超能文献

一种基于聚氯乙烯(PVC)膜中2-巯基嘧啶的汞离子光学化学传感器。

An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane.

作者信息

Khezri Bahareh, Amini Mohammad K, Firooz Ali R

机构信息

Chemistry Department, University of Isfahan, Isfahan, 81746-73441, Iran.

出版信息

Anal Bioanal Chem. 2008 Apr;390(7):1943-50. doi: 10.1007/s00216-008-1906-2. Epub 2008 Mar 3.

Abstract

An optical chemical sensor based on 2-mercaptopyrimidine (2-MP) in plasticized poly(vinyl chloride) (PVC) membrane incorporating (N,N-diethyl-5-(octadecanoylimino)-5H benzo[a]phenoxazine-9-amine (ETH 5294) and sodium tetraphenyl borate (NaTPB) for batch and flow-through determination of mercury ion is described. The response of the sensor is based on selective complexation of Hg(2+) with 2-MP in the membrane phase, resulting in an ion exchange process between H(+) in the membrane and Hg(2+) in the sample solution. The influences of several experimental parameters, such as membrane composition, pH, and type and concentration of the regenerating reagent, were investigated. The sensor has a response range of 2.0 x 10(-9) to 2.0 x 10(-5) mol L(-1) Hg(2+) with a detection limit of 4.0 x 10(-10) mol L(-1) and a response time of < or = 45 s at optimum pH of 6.5 with high measurement repeatability and sensor-to-sensor reproducibility. It shows high selectivity for Hg(2+) over several transition metal ions, including Ag(+), Cd(2+), Co(2+), Cr(3+), Cu(2+), Fe(3+), Mn(2+), Ni(2+), and common alkali and alkaline earth ions such as Na(+), K(+), Mg(2+), Ca(2+), and Pb(2+). The sensor membrane can be easily regenerated with dilute acid solutions. The sensor has been used for the determination of mercury ion concentration in water samples.

摘要

本文描述了一种基于2-巯基嘧啶(2-MP)的光学化学传感器,该传感器采用增塑聚氯乙烯(PVC)膜,其中含有(N,N-二乙基-5-(十八烷酰亚氨基)-5H苯并[a]吩恶嗪-9-胺(ETH 5294)和四苯基硼酸钠(NaTPB),用于分批和流通式测定汞离子。该传感器的响应基于膜相中Hg(2+)与2-MP的选择性络合,导致膜中的H(+)与样品溶液中的Hg(2+)之间发生离子交换过程。研究了几个实验参数的影响,如膜组成、pH值以及再生试剂的类型和浓度。该传感器对Hg(2+)的响应范围为2.0×10(-9)至2.0×10(-5) mol L(-1),检测限为4.0×10(-10) mol L(-1),在最佳pH值6.5时响应时间≤45 s,具有高测量重复性和传感器间重现性。它对Hg(2+)的选择性高于几种过渡金属离子,包括Ag(+)、Cd(2+)、Co(2+)、Cr(3+)、Cu(2+)、Fe(3+)、Mn(2+)、Ni(2+),以及常见的碱金属和碱土金属离子,如Na(+)、K(+)、Mg(2+)、Ca(2+)和Pb(2+)。该传感器膜可用稀酸溶液轻松再生。该传感器已用于测定水样中的汞离子浓度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验