Suppr超能文献

用于复发性晕厥的植入式循环记录仪:静息心电图显示的心脏传导异常及潜在心脏疾病对随访进展的影响。

Implantable loop recorder for recurrent syncope: influence of cardiac conduction abnormalities showing up on resting electrocardiogram and of underlying cardiac disease on follow-up developments.

作者信息

Pierre Bertrand, Fauchier Laurent, Breard Guillaume, Marie Olivier, Poret Philippe, Babuty Dominique

机构信息

Service de cardiologie B et laboratoire d'electrophysiologie cardiaque, Pôle Coeur Vaisseaux Thorax et Hémostase, Centre Hospitalier Universitaire Trousseau, 37044 Routes de Loches, Tours, Indre et Loire, France.

出版信息

Europace. 2008 Apr;10(4):477-81. doi: 10.1093/europace/eun039. Epub 2008 Mar 5.

Abstract

AIMS

The implantable loop recorder is a useful diagnostic tool in dealing with recurrent syncope in patients. We tested to determine the influence of cardiac conduction abnormalities that turn up on resting electrocardiogram (ECG) and the impact of underlying cardiac disease on developments during follow-up.

METHODS AND RESULTS

Ninety-five consecutive patients received an implantable loop recorder to monitor recurrent syncope (n = 4.9+/-3.8) of unknown aetiology after cardiac investigations, including an electrophysiological study. Resting ECG was abnormal, suggesting an arrhythmic syncope, in 29 (30.5%) patients, while 21 (22.1%) patients had an underlying cardiac disease. During an average follow-up period of 10.2+/-5.2 months, 43 (45.2%) patients developed a new syncope associated in 27 of them (62.8%) with an arrhythmic event. Syncope was no more frequent in the subgroup of patients with cardiac conduction abnormalities on resting ECG, while the frequency of arrhythmic events was similar whether or not the ECG was normal. In the subgroup of patients with cardiac disease with normal left ventricular ejection fraction, the occurrence of syncope was less frequent, and the number of arrhythmic events was no greater in these patients.

CONCLUSION

Implantable loop recorder is a useful diagnostic tool for recurrent syncope of unknown aetiology.

摘要

目的

植入式循环记录仪是处理患者反复晕厥的一种有用的诊断工具。我们进行测试以确定静息心电图(ECG)出现的心脏传导异常的影响以及潜在心脏病对随访期间病情发展的影响。

方法与结果

95例连续患者接受了植入式循环记录仪,以监测在包括电生理研究在内的心脏检查后病因不明的反复晕厥(n = 4.9±3.8)情况。29例(30.5%)患者静息ECG异常,提示心律失常性晕厥,而21例(22.1%)患者有潜在心脏病。在平均10.2±5.2个月的随访期内,43例(45.2%)患者出现了新的晕厥,其中27例(62.8%)与心律失常事件相关。静息ECG有心脏传导异常的患者亚组中晕厥并不更频繁,无论ECG是否正常,心律失常事件的发生率相似。在左心室射血分数正常的心脏病患者亚组中,晕厥的发生率较低,且这些患者的心律失常事件数量也未增加。

结论

植入式循环记录仪是病因不明的反复晕厥的一种有用的诊断工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验