文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Reproducibility of infrared thermography measurements in healthy individuals.

作者信息

Zaproudina Nina, Varmavuo Ville, Airaksinen Olavi, Närhi Matti

机构信息

Institute of Biomedicine, Department of Physiology, University of Kuopio, PO Box 1627, FIN-70211, Finland.

出版信息

Physiol Meas. 2008 Apr;29(4):515-24. doi: 10.1088/0967-3334/29/4/007. Epub 2008 Apr 9.


DOI:10.1088/0967-3334/29/4/007
PMID:18401069
Abstract

The aim of this study was to investigate the reproducibility of skin surface infrared thermography (IRT) measurements and determine the factors influencing the variability of the measured values. While IRT has been widely utilized in different clinical conditions, there are few available data on the values of the skin temperature patterns of healthy subjects and their reproducibility. We recorded the whole body skin temperatures of sixteen healthy young men with two observers on two consecutive days. The results were compared using intra-class correlations analyses (ICC). The inter-examiner reproducibility of the IRT measurements was high: mean ICC 0.88 (0.73-0.99). The day-to-day stability of thermal patterns varied depending on the measured area: it was high in the core and poor in distal areas. The reproducibility of the side-to-side temperature differences (deltaT) was moderately good between the two observers (mean ICC 0.68) but it was reduced with time, especially in the extremities, mean ICC 0.4 (-0.01-0.83). The results suggest that the IRT technique may represent an objective quantifiable indicator of autonomic disturbances although there are considerable temporal variations in the measured values which are due to both technical factors such as equipment accuracy, measurement environment and technique, and physiological variability of the blood flow, and these factors should be taken into account.

摘要

相似文献

[1]
Reproducibility of infrared thermography measurements in healthy individuals.

Physiol Meas. 2008-4

[2]
Comparison of infrared thermography and laser speckle contrast imaging for the dynamic assessment of digital microvascular function.

Microvasc Res. 2011-7-1

[3]
Are the infrared thermography findings skin temperature-dependent? a study on neck pain patients.

Skin Res Technol. 2012-10-1

[4]
Validation of a protocol for the assessment of skin temperature and blood flow in childhood localised scleroderma.

Skin Res Technol. 2009-8

[5]
Paraspinal skin temperature patterns: an interexaminer and intraexaminer reliability study.

J Manipulative Physiol Ther. 2004

[6]
Reliability of an infrared forehead skin thermometer for core temperature measurements.

J Med Eng Technol. 2006

[7]
Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography.

Physiol Meas. 2014-1-7

[8]
[Contemporary applications of infrared imaging in medical diagnostics].

Ann Acad Med Stetin. 2006

[9]
Comparison of temporal artery, mid-forehead skin and axillary temperature recordings in preterm infants <1500 g of birthweight.

J Paediatr Child Health. 2009

[10]
Infrared tympanic temperature and ear canal morphology.

J Med Eng Technol. 2006

引用本文的文献

[1]
Preliminary study on objective evaluation algorithm of human infrared thermogram seriality and its clinical application in population with metabolic syndrome.

BMJ Health Care Inform. 2025-6-26

[2]
Current Use of Infrared Thermography in Orthopaedic and Bone or Joint Trauma Patients-Can We Identify Postoperative Infection? A Narrative Systematic Review.

Strategies Trauma Limb Reconstr. 2024

[3]
Water retention influences thigh skin temperature variation post-exercise: preliminary study of bioimpedance analysis and thermography data.

Front Sports Act Living. 2025-2-14

[4]
The influence of static and dynamic warm-up on knee temperature: infrared thermography insights before and after a change of direction exercise.

Front Physiol. 2024-8-1

[5]
Active Breaks Reduce Back Overload during Prolonged Sitting: Ergonomic Analysis with Infrared Thermography.

J Clin Med. 2024-5-29

[6]
Influence of changes in foot morphology and temperature on bruised toenail injury risk during running.

Sci Rep. 2024-1-21

[7]
Thermographic examination of gingival phenotypes: correlation between morphological and thermal parameters.

Clin Oral Investig. 2023-12

[8]
Determination of the Effects of a Series of Ten Whole-Body Cryostimulation Sessions on Physiological Responses to Exercise and Skin Temperature Behavior following Exercise in Elite Athletes.

J Clin Med. 2023-9-24

[9]
A century of exercise physiology: concepts that ignited the study of human thermoregulation. Part 2: physiological measurements.

Eur J Appl Physiol. 2023-12

[10]
Infrared Thermography Imaging for Assessment of Peripheral Perfusion in Patients with Septic Shock.

Bioengineering (Basel). 2023-6-18

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索