Koidl Christoph, Bozic Michael, Hadzisejdic Ita, Grahovac Maja, Grahovac Blazenka, Kranewitter Wolfgang, Marth Egon, Kessler Harald H
Molecular Diagnostics Laboratory, Institute of Hygiene, Medical University of Graz, Graz, Austria.
Am J Obstet Gynecol. 2008 Aug;199(2):144.e1-6. doi: 10.1016/j.ajog.2008.03.005. Epub 2008 Apr 25.
The objective of the study was to compare the performance of 3 different extraction instruments in conjunction with 4 different amplification and detection kits for detection and typing of human papillomavirus (HPV) deoxyribonucleic acid (DNA).
A total of 42 cervical swabs were investigated. HPV DNA was extracted on the 3 different instruments. Each of the extracts was then amplified, and HPV DNA amplification products were detected with 4 different kits.
In 31 samples, HPV DNA was detected by both the Amplicor HPV test and the LINEAR ARRAY HPV genotyping test in conjunction with DNA extraction on the easyMAG instrument. In another 6 samples, only low-risk types were detected with the linear array HPV genotyping test. After extraction on the easyMAG instrument, 32 samples tested positive when the PapilloCheck with the HotStarTaq DNA polymerase was used.
Together with extraction on the easyMAG instrument, the Amplicor HPV test, the linear array HPV genotyping test, and the new PapilloCheck with the HotStarTaq DNA polymerase provide comparable results allowing reliable and safe HPV diagnostics in the routine laboratory. Use of alternative assays may lead to an increase of invalid and divergent HPV typing results.
本研究的目的是比较3种不同提取仪器与4种不同扩增和检测试剂盒联合使用时,对人乳头瘤病毒(HPV)脱氧核糖核酸(DNA)进行检测和分型的性能。
共调查了42份宫颈拭子。在3种不同仪器上提取HPV DNA。然后对每份提取物进行扩增,并用4种不同试剂盒检测HPV DNA扩增产物。
在31份样本中,使用易磁珠仪器提取DNA时,Amplicor HPV检测法和线性阵列HPV基因分型检测法均检测到HPV DNA。在另外6份样本中,线性阵列HPV基因分型检测法仅检测到低风险型。在易磁珠仪器上提取DNA后,当使用含HotStarTaq DNA聚合酶的PapilloCheck检测时,32份样本检测呈阳性。
与在易磁珠仪器上提取DNA一起,Amplicor HPV检测法、线性阵列HPV基因分型检测法以及含HotStarTaq DNA聚合酶的新型PapilloCheck检测法提供了可比的结果,使得在常规实验室中进行可靠且安全的HPV诊断成为可能。使用其他检测方法可能会导致无效和不同的HPV分型结果增加。