Jankelevich J, Vásquez M, Valverde V, Astudillo J, Valdés E, Concha J, Ferrer L
Departamento de Obstetricia y Ginecología, Hospital Clínico J. J. Aguirre, Universidad de Chile.
Rev Chil Obstet Ginecol. 1991;56(1):35-7.
Vibratory acoustic stimulation was done in patients with an abnormal fetal heart rate tracing in external continuous electronic monitoring during labor, correlating with Apgar score, meconium staining and umbilical cord pH, describing a 83.3% sensitivity, 81.3% specificity and 62.5% positive predictive value. The authors recommend the use of vibratory acoustic stimulation in those cases with an abnormal fetal heart rate tracing in external continuous electronic monitoring, when we can not install internal electronic monitoring or obtain a fetal blood pH on assessment of fetal well-being.