[全膝关节置换术中的计算机辅助手术。初步结果:60例报告]

[Computer-assisted surgery in total knee replacement. Preliminary results: report of 60 cases].

作者信息

El Masri F, Rammal H, Ghanem I, El Hage S, El Abiad R, Kharrat K, Dagher F

机构信息

Hôpital Hôtel-Dieu-de-France, université Saint-Joseph, boulevard Alfred-Naccache, Achrafieh, B.P. 166099, Beyrouth, Lebanon.

出版信息

Rev Chir Orthop Reparatrice Appar Mot. 2008 May;94(3):261-7. doi: 10.1016/j.rco.2007.10.005. Epub 2008 Feb 21.

Abstract

PURPOSE OF THE STUDY

Conventional techniques proposed for total knee arthroplasty (TKA), necessarily require an acceptable alignment of the lower limb. Computer-assisted surgery is becoming increasingly popular in order to improve the precision of the component alignment, an essential element for good long-term results. The purpose of this prospective study was to present our preliminary results with computer-assisted implantation of TKA.

MATERIAL AND METHODS

This was a prospective study of 55 patients (60 knees) included at random for computer-assisted TKA between April 2004 and September 2005. Mean age was 70.5 years. The preoperative assessment noted genu varum in 56 knees and genu valgum in four knees. Three knees with unilateral degenerative disease presented a post traumatic tibia malunion. The same surgeon performed all of the operations using the same prosthesis and navigation system (P.F.C. Sigma). Lower limb alignment and orientation of the prosthetic implants were assessed with standard pre- and postoperative gonometry. Sagittal alignment was measured on the standard X-rays (lateral and anteroposterior view).

RESULTS

Knee alignment improved from 8.1+/-4.5 degrees varus (10 degrees valgus to 18 degrees varus) preoperatively, to 0.4+/-0.6 degrees varus (1 degrees valgus to 2 degrees varus) postoperatively. In the frontal plane, the mean angle of the femoral component on the anteroposterior (ap) view was 89.7+/-0.7 degrees (88-91 degrees). The mean angle of the tibial component on the ap view was 89.9+/-0.7 degrees (88.5-91 degrees). The femorotibial mechanical axis was within +/-2 degrees for all prostheses. In the sagittal plane, the mean angle of the femoral component on the lateral view was 4.8 degrees (3-6.5 degrees). The mean tibial slope was 2.7 degrees (1-4 degrees) for the prostheses with a fixed tibial plateau and 0.2 degrees (-1 degrees to +1 degrees) for those with a rotating plateau. The mean operative time was 135 min (110-180 min) and was inversely proportional to experience. There was one conversion to conventional surgery due to software dysfunction. There were no complications related to the operative technique.

DISCUSSION

The best outcome, particularly in terms of aseptic loosening, is reported for knees with a valgus or varus angle within 3 degrees . The improved accuracy of computer-assisted implantation has enabled better orientation of the components in the frontal, sagittal and horizontal planes with implantations well within this range.

摘要

研究目的

全膝关节置换术(TKA)所采用的传统技术必然要求下肢有可接受的对线。计算机辅助手术正日益普及,以提高假体组件对线的精度,这是获得良好长期效果的关键要素。本前瞻性研究的目的是展示我们在计算机辅助下进行TKA植入的初步结果。

材料与方法

这是一项对2004年4月至2005年9月期间随机纳入的55例患者(60个膝关节)进行的计算机辅助TKA前瞻性研究。平均年龄为70.5岁。术前评估发现56个膝关节有膝内翻,4个膝关节有膝外翻。3个单侧退行性疾病膝关节存在创伤后胫骨畸形愈合。所有手术均由同一位外科医生使用相同的假体和导航系统(P.F.C. Sigma)进行。术前和术后采用标准测角法评估下肢对线和假体植入物的方向。矢状面的对线在标准X线片(侧位和前后位)上进行测量。

结果

膝关节对线从术前的内翻8.1±4.5度(外翻10度至内翻18度)改善至术后的内翻0.4±0.6度(外翻1度至内翻2度)。在额状面,前后位(ap)视图中股骨组件的平均角度为89.7±0.7度(88 - 91度)。ap视图中胫骨组件的平均角度为89.9±0.7度(88.5 - 91度)。所有假体的股胫机械轴均在±2度范围内。在矢状面,侧位视图中股骨组件的平均角度为4.8度(3 - 6.5度)。对于固定胫骨平台的假体,平均胫骨坡度为2.7度(1 - 4度);对于旋转平台的假体,平均胫骨坡度为0.2度(-1度至 +1度)。平均手术时间为135分钟(110 - 180分钟),且与经验成反比。因软件故障有1例转为传统手术。未发生与手术技术相关的并发症。

讨论

据报道,对于外翻或内翻角度在3度以内的膝关节,尤其是在无菌性松动方面,效果最佳。计算机辅助植入的精度提高使得组件在额状面、矢状面和水平面的方向更好,植入均在此范围内。