Suppr超能文献

使用具有拟调节功能的人工晶状体进行晶状体置换术后的眼的光学质量。

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens.

作者信息

Montés-Micó Robert, Ferrer-Blasco Teresa, Charman W Neil, Cerviño Alejandro, Alfonso José F, Fernández-Vega Luis

机构信息

Optometry Research Group, Optics Department, Faculty of Physics, University of Valencia, Valencia, Spain.

出版信息

J Cataract Refract Surg. 2008 May;34(5):763-8. doi: 10.1016/j.jcrs.2008.01.017.

Abstract

PURPOSE

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.

SETTING

University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.

METHODS

Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (< or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective distances. Wavefront aberrations were measured before and after surgery. Aberrations for 2 pupil diameters (3.0 mm and 5.0 mm) were decomposed using Zernike polynomials; total, defocus, astigmatism spherical, and coma aberration terms were studied separately. Postimplantation results were compared with preoperative values.

RESULTS

Safety and efficacy indices for distance vision were 1.01 and 0.96, respectively. At near, they improved to 1.07 and 1.06, respectively. Vision at intermediate distances was noticeably poorer. Total, defocus, and spherical aberrations changed after IOL implantation with both pupil diameters (P<.01). Total and defocus aberrations were significantly reduced postoperatively. Spherical aberration coefficients changed to negative and less positive values for a 3.0 mm and a 5.0 mm pupil, respectively.

CONCLUSIONS

Implantation of the pseudoaccommodating IOL in healthy eyes yielded uncorrected levels of high-contrast, distance, and near acuities comparable to preoperative best corrected values. Higher-order aberration levels appeared to be similar to the preoperative values.

摘要

目的

通过测量视力和波前像差,研究植入伪调节性AcrySof ReSTOR Natural人工晶状体(IOL)(爱尔康实验室)前后健康老视眼的光学质量。

地点

西班牙巴伦西亚费尔南德斯 - 维加眼科研究所,巴伦西亚大学。

方法

对30例低散光(≤1.00 D)的老视远视眼(+0.50至 +4.00屈光度[D])进行双侧AcrySof ReSTOR Natural IOL植入透明晶状体摘除术前和术后的单眼验光以及明视距离(6 m)和近视力(0.33 m)测定。在一系列有效距离上测量术后双眼视力。测量手术前后的波前像差。使用泽尼克多项式分解2种瞳孔直径(3.0 mm和5.0 mm)的像差;分别研究总像差、离焦、散光、球差和彗差项。将植入后的结果与术前值进行比较。

结果

远视力的安全性和有效性指数分别为1.01和0.96。在近视力方面,它们分别提高到1.07和1.06。中距离视力明显较差。两种瞳孔直径下IOL植入后总像差、离焦和球差均发生变化(P<0.01)。术后总像差和离焦像差显著降低。对于3.0 mm和5.0 mm的瞳孔,球差系数分别变为负值和较小的正值。

结论

在健康眼中植入伪调节性IOL可产生与术前最佳矫正值相当的未矫正高对比度、远视力和近视力水平。高阶像差水平似乎与术前值相似。