Salci Hakan, Sarigul Sani, Dogan Seref, Lekesiz Huseyin, Ozcan Resat, Gorgul O Sacit, Aksoy Kaya
Department of Surgery, Faculty of Veterinary Medicine, Uludag University, Bursa, Turkey.
J Vet Sci. 2008 Jun;9(2):193-6. doi: 10.4142/jvs.2008.9.2.193.
We performed biomechanical comparison of a xenograft bone plate-screw (XBPS) system for achieving cadaveric lumbar transpedicular stabilization (TS) in dogs. Twenty dogs' cadaveric L(2-4) lumbar specimens were harvested and their muscles were removed, but the discs and ligaments were left intact. These specimens were separated to four groups: the L(2-4) intact group as control (group I, n = 5), the L(3) laminectomy and bilateral facetectomy group (LBF) (group II, n = 5), the LBF plus TS with metal plate-screw group (group III, n = 5) and the LBF plus TS with XBPS group (group IV, n = 5). Five kinds of biomechanical tests were applied to the specimens: flexion, extension, left-right bending and rotation. The averages of the 16 stiffness values were calculated and then these were statistically analyzed. The statistical results show that the XBPS system contributes spinal stability and this system can be a good choice for achieving TS.
我们对一种用于犬尸体腰椎经椎弓根固定(TS)的异种移植骨板螺钉(XBPS)系统进行了生物力学比较。采集了20只犬的L(2 - 4)腰椎尸体标本并去除其肌肉,但保留椎间盘和韧带完整。这些标本被分为四组:L(2 - 4)完整组作为对照组(I组,n = 5),L(3)椎板切除术和双侧小关节切除术组(LBF)(II组,n = 5),LBF加金属板螺钉固定的TS组(III组,n = 5)以及LBF加XBPS固定的TS组(IV组,n = 5)。对标本进行了五种生物力学测试:前屈、后伸、左右侧屈和旋转。计算了16个刚度值的平均值,然后对这些值进行统计学分析。统计结果表明,XBPS系统有助于脊柱稳定,该系统可成为实现TS的良好选择。