Brown Elizabeth T, Saunders Susan E, Zaslau Stanley
Division of Urology, West Virginia University, Morgantown, WV 26506, USA.
J Sex Med. 2008 Dec;5(12):2960-2. doi: 10.1111/j.1743-6109.2008.00868.x. Epub 2008 May 21.
Erosion of penile prosthesis tubing represents a late complication of penile prosthesis surgery. To our knowledge, this is the first report of isolated erosion of penile implant pump tubing into the urethra in an otherwise asymptomatic patient. The patient had no signs of infection or erosion and no voiding complaints. His only problem was that his urinary catheter was not able to be placed during his vascular surgery procedure.
Patient with a 5-year history of erectile dysfunction refractory to therapy with PDE5 inhibitors, injection therapy, and vacuum erection device therapy underwent placement of an Alpha-1 Mentor inflatable penile prosthesis. The patient underwent femoral-popliteal bypass at month 21, and during the procedure, the vascular service was unable to place a urinary catheter. Erosion of the tubing from his penile prosthesis was then noted at approximately the junction between the membranous and bulbar urethra.
Patient was without signs of infection and had no voiding complaints. These findings were discovered because of the inability to place a urinary catheter for his femoral-popliteal bypass. Diagnosis was made by flexible cystoscopy.
No evidence of infection was noted on examination, and the patient was otherwise asymptomatic. Diagnosis can be made by flexible cystoscopy. Subsequent removal of the penile implant was curative.
阴茎假体导管侵蚀是阴茎假体手术的一种晚期并发症。据我们所知,这是首例关于阴茎植入泵导管在无症状患者中孤立性侵蚀入尿道的报告。该患者没有感染或侵蚀迹象,也没有排尿方面的主诉。他唯一的问题是在血管手术过程中无法插入导尿管。
一名患有勃起功能障碍5年的患者,对磷酸二酯酶5抑制剂、注射治疗及真空勃起装置治疗均无效,接受了Alpha-1 Mentor可膨胀阴茎假体植入术。患者在术后21个月接受了股腘动脉搭桥手术,在此过程中,血管外科无法插入导尿管。随后在膜部尿道和球部尿道交界处附近发现了阴茎假体导管的侵蚀。
患者没有感染迹象,也没有排尿方面的主诉。这些发现是由于在股腘动脉搭桥手术中无法插入导尿管而被发现的。通过软性膀胱镜检查做出诊断。
检查未发现感染证据,且患者无其他症状。可通过软性膀胱镜检查做出诊断。随后取出阴茎植入物可治愈该疾病。