McDermott M L, Watsky M A, Geroski D H, Edelhauser H F
Department of Ophthalmology, Wayne State University, Detroit, Michigan.
Cornea. 1991 Jan;10(1):44-9.
Endothelial permeability (Pac) to carboxyfluorescein and Na+/K+ ATPase pump site density were determined in human corneas following storage for 4 or 7 days at 4 degrees C in either modified McCarey-Kaufman (mMK) or K-Sol media. Following 4 days of storage, Pac values for mMK- and K-Sol-preserved corneas were not significantly different from those of their prestorage mates. After 7 days of storage, however, corneas stored in K-Sol media showed a significant increase in Pac compared to their prestorage mates, whereas the mMK-stored corneas showed no change in Pac. Na+/K+ ATPase pump site density determined using [3H]ouabain was similar to a control group in the K-Sol-stored tissue but higher in the mMK-stored tissue following 7 days of storage. These studies suggest that mMK medium maintains endothelial barrier function and Na+/K+ ATPase pump site density at least as well as K-Sol medium through 7 days of corneal storage.
在改良的麦卡里 - 考夫曼(mMK)或K - 索尔培养基中于4℃储存4天或7天后,测定人角膜对羧基荧光素的内皮通透性(Pac)以及Na⁺/K⁺ ATP酶泵位点密度。储存4天后,mMK和K - 索尔保存的角膜的Pac值与其储存前的配对角膜相比无显著差异。然而,储存7天后,与储存前的配对角膜相比,储存在K - 索尔培养基中的角膜的Pac显著增加,而mMK储存的角膜的Pac没有变化。使用[³H]哇巴因测定的Na⁺/K⁺ ATP酶泵位点密度在K - 索尔储存的组织中与对照组相似,但在储存7天后,mMK储存的组织中该密度更高。这些研究表明,在角膜储存7天的过程中,mMK培养基至少与K - 索尔培养基一样能维持内皮屏障功能和Na⁺/K⁺ ATP酶泵位点密度。