Wöstmann Bernd, Rehmann Peter, Balkenhol Markus
Department of Prosthodontics, Justus-Liebig-University, Giessen, Germany.
Int J Prosthodont. 2008 May-Jun;21(3):215-6.
This study aimed to analyze the influence of different retraction techniques (pure cotton cord, cord impregnated with epinephrine, and chemical retraction [Expa-syl]) on the crevicular fluid flow in vivo. A total of 340 prepared teeth were randomly assigned to one of the retraction procedures. Crevicular fluid flow was measured prior to and immediately after the removal of the respective retraction material. Pure cotton cords led to a significant increase in crevicular fluid flow, whereas impregnated cords and Expa-syl significantly reduced crevicular fluid flow (P < .01). The retraction technique has a high impact on the reduction of crevicular fluid flow in patients. Pure cotton retraction cords should be avoided.
本研究旨在分析不同排龈技术(纯棉排龈线、含肾上腺素排龈线和化学排龈[Expa-syl])对体内龈沟液流量的影响。总共340颗预备牙被随机分配至一种排龈程序。在去除相应排龈材料之前和之后立即测量龈沟液流量。纯棉排龈线导致龈沟液流量显著增加,而含药排龈线和Expa-syl显著降低龈沟液流量(P < 0.01)。排龈技术对患者龈沟液流量的减少有很大影响。应避免使用纯棉排龈线。