Bello R A, Robinson C W, Moo-Young M
Biochemical Engineering Group, Department of Chemical Engineering, University of Waterloo, Waterloo, Ontario, Canada.
Biotechnol Bioeng. 1985 Mar;27(3):369-81. doi: 10.1002/bit.260270323.
The two major types of airlift contactors, concentric-tube and external-loop, were investigated for their gas holdup (riser and downcomer) and overall mass transfer characteristics. Results obtained in batch charges of tap water and 0.15 kmol/m(3) NaCl solution are reported for external-loop airlift contactors having downcomer-to-riser cross-sectional area ratios, A(d)/A(r), ranging from 0.11 <or= A(d)/A(r) <or= 0.69 and for concentric-tube types in the range 0.13 <or= A(d)/A(r) <or= 0.56.The results are compared and contrasted for the two types of airlift contactors and also with corresponding results obtained in a bubble column (A(d)/A(r) = 0). Both the riser gas holdup, (epsilon(G))(r), and the overall volumetric mass transfer coefficient, (K(L)a(D))(T), were found to increase with increasing gas superficial velocity and the corresponding specific gassing power input, (P(G)/V(D))(T). However, at a specified power input both (epsilon(G))(r) and (K(L)a(D))(T) decreased with increasing A(d)/A(r) due to a resultant increase in circulating liquid velocity. Unifying generalized correlations for both types of airlift contactors are given for both (epsilon(G))(r) and (K(L)a(D))(T). These correlations are expected to be applicable as well to continuous-liquid flow bubble columns at comparable liquid velocities.
研究了气升式接触器的两种主要类型,即同心管型和外环型,考察了它们的气含率(提升管和降液管)及整体传质特性。报告了在分批装入自来水和0.15 kmol/m³氯化钠溶液的情况下,降液管与提升管横截面积比A(d)/A(r)在0.11≤A(d)/A(r)≤0.69范围内的外环型气升式接触器以及A(d)/A(r)在0.13≤A(d)/A(r)≤0.56范围内的同心管型接触器的相关结果。对这两种气升式接触器的结果进行了比较和对比,同时也与鼓泡塔(A(d)/A(r)=0)中得到的相应结果进行了比较。结果发现,提升管气含率(ε(G))(r)和整体体积传质系数(K(L)a(D))(T)均随气体表观速度和相应的比通气功率输入(P(G)/V(D))(T)的增加而增大。然而,在给定的功率输入下,由于循环液体速度的相应增加,(ε(G))(r)和(K(L)a(D))(T)均随A(d)/A(r)的增加而减小。给出了两种气升式接触器(ε(G))(r)和(K(L)a(D))(T)的统一通用关联式。预计这些关联式在可比液体速度下也适用于连续液体流动鼓泡塔。