Visch L L, Bergveld P, Lamprecht W, 's-Gravenmade E J
Dr. Daniel den Hoed Cancer Center, Rotterdam Radio-Therapeutic Institute, The Netherlands.
IEEE Trans Biomed Eng. 1991 Apr;38(4):353-6. doi: 10.1109/10.133230.
A transistor pH electrode (ion sensitive field effect transistor), placed in the upper dentures of eleven xerostomia patients and five healthy volunteers, was used to register pH changes in five-, six- and seven-day-old dental plaque. A mouth rinse with a 10% sucrose solution caused a pH fall of about three decades. A significant difference in duration of critical plaque pH was observed: in xerostomia patients, a 10% longer period of pH less than 5.7 was registered during 60 min following a sucrose rinse. Normal oral functions were not influenced by the denture with an integrated electrode. This method is usable for plaque pH registration in xerostomia patients.
将一个晶体管pH电极(离子敏感场效应晶体管)置于11名口干症患者和5名健康志愿者的上假牙中,用于记录5日、6日和7日龄牙菌斑中的pH变化。用10%的蔗糖溶液漱口会导致pH值下降约三个数量级。观察到临界菌斑pH持续时间存在显著差异:在口干症患者中,蔗糖漱口后60分钟内记录到pH值低于5.7的时间延长了10%。集成电极的假牙未影响正常口腔功能。该方法可用于记录口干症患者的菌斑pH值。