• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Influence of balloon size and stenosis morphology on immediate and delayed elastic recoil after percutaneous transluminal coronary angioplasty.

作者信息

Hanet C, Wijns W, Michel X, Schroeder E

机构信息

Division of Cardiology, University of Louvain Medical School, Brussels, Belgium.

出版信息

J Am Coll Cardiol. 1991 Aug;18(2):506-11. doi: 10.1016/0735-1097(91)90607-b.

DOI:10.1016/0735-1097(91)90607-b
PMID:1856419
Abstract

After successful coronary angioplasty, the minimal luminal diameter of the dilated coronary artery segment is generally smaller than the diameter of the largest balloon catheter at the maximal inflation pressure. The determinants of this phenomenon were studied in 28 patients. Biplane angiograms were obtained after intracoronary administration of isosorbide dinitrate (1 mg) before, immediately and 24 h after coronary angioplasty. Balloon and coronary luminal diameters were measured by automated contour detection. Immediately after the procedure, the difference between inflated balloon diameter and minimal luminal diameter averaged 0.93 +/- 0.43 mm for the entire group and was greater both in eccentric stenoses (1.13 +/- 0.39 vs. 0.70 +/- 0.36 mm; p less than 0.01) and after angioplasty with an oversized balloon (1.20 +/- 0.37 vs. 0.71 +/- 0.33 mm; p less than 0.005). At 24 h, the balloon - minimal luminal diameter difference was unchanged at the group level (0.86 +/- 0.38 mm, but the minimal luminal diameter increased significantly in the subgroup of coronary segments dilated with an oversized balloon (1.97 +/- 0.37 vs. 1.81 +/- 0.28 mm; p less than 0.05). Thus, the difference between the minimal diameter of a dilated coronary segment immediately after a successful coronary balloon angioplasty procedure and the maximal diameter of the inflated balloon catheter is dependent both on eccentricity of the stenosis and on the balloon/artery diameter ratio. Moreover, the increase in minimal luminal diameter 24 h after angioplasty performed with an oversized balloon suggest that in addition to elastic recoil partly reversible factors related to vessel barotrauma are involved.

摘要

相似文献

1
Influence of balloon size and stenosis morphology on immediate and delayed elastic recoil after percutaneous transluminal coronary angioplasty.
J Am Coll Cardiol. 1991 Aug;18(2):506-11. doi: 10.1016/0735-1097(91)90607-b.
2
Elastic recoil following percutaneous transluminal coronary angioplasty and Palmaz-Schatz stent implantation.经皮腔内冠状动脉成形术及Palmaz-Schatz支架植入后的弹性回缩
J Invasive Cardiol. 1995 Jul-Aug;7(6):165-72.
3
Regional differences in elastic recoil after percutaneous transluminal coronary angioplasty: a quantitative angiographic study.
J Am Coll Cardiol. 1991 May;17(6 Suppl B):34B-38B. doi: 10.1016/0735-1097(91)90936-4.
4
Influence of elastic recoil on restenosis after successful coronary angioplasty in unstable angina pectoris.弹性回缩对不稳定型心绞痛患者成功进行冠状动脉血管成形术后再狭窄的影响。
Am J Cardiol. 1993 Mar 15;71(8):659-63. doi: 10.1016/0002-9149(93)91006-4.
5
Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents.球囊血管成形术后及冠状动脉内植入球囊扩张式Palmaz-Schatz支架后的弹性回缩定量分析。
J Am Coll Cardiol. 1993 Jan;21(1):26-34. doi: 10.1016/0735-1097(93)90713-b.
6
Angiographic patterns of balloon inflation during percutaneous transluminal coronary angioplasty: role of pressure-diameter curves in studying distensibility and elasticity of the stenotic lesion and the mechanism of dilation.经皮腔内冠状动脉成形术期间球囊充盈的血管造影模式:压力-直径曲线在研究狭窄病变的扩张性和弹性以及扩张机制中的作用。
J Am Coll Cardiol. 1990 Sep;16(3):569-75. doi: 10.1016/0735-1097(90)90344-o.
7
Incidence and treatment of elastic recoil occurring in the 15 minutes following successful percutaneous transluminal coronary angioplasty.经皮腔内冠状动脉成形术成功后15分钟内发生弹性回缩的发生率及治疗
Am J Cardiol. 1996 Aug 1;78(3):253-9. doi: 10.1016/s0002-9149(96)00273-1.
8
[Effect of high insufflation pressures on elastic recoil forces and vascular resistance after balloon dilatation].[高充气压力对球囊扩张后弹性回缩力和血管阻力的影响]
Z Kardiol. 1996 Apr;85(4):273-80.
9
[The angiographic evaluation of elastic recoil after coronary angioplasty].
Cardiologia. 1992 Aug;37(8):533-7.
10
Quantitative angiographic assessment of elastic recoil after percutaneous transluminal coronary angioplasty.经皮腔内冠状动脉成形术后弹性回缩的定量血管造影评估。
Am J Cardiol. 1990 Nov 1;66(15):1039-44. doi: 10.1016/0002-9149(90)90501-q.