Brinkman U A, De Kok A, De Vries G, Reymer H G
J Chromatogr. 1976 Nov 17;128(1):101-10. doi: 10.1016/s0021-9673(00)84035-2.
High-speed liquid chromatography in the system silica gel/dry n-hexane and ultraviolet spectrometry have been used to study the composition of various types of commercially available mixtures of chlorinated biphenyls. Special attention has been paid to the analysis of highly chlorinated products. In addition to data previously published, retention times are recorded for 11 individual polychlorinated biphenyls. The results of high-speed liquid chromatography are compared with those obtained in several normal and reversed-phase thin-layer chromatographic systems.
在硅胶/干燥正己烷体系中采用高效液相色谱法以及紫外光谱法,对各类市售氯化联苯混合物的成分进行了研究。特别关注了高氯化产物的分析。除了先前发表的数据外,还记录了11种单独的多氯联苯的保留时间。将高效液相色谱的结果与在几种正相和反相薄层色谱系统中获得的结果进行了比较。