Abstract

Ischemia of the airway is the main cause of severe complications in lung transplantation. Tissue-pH is used as an indicator of ischemia in the myocardium and various other tissues. We developed a pH needle probe which can be applied through a bronchoscope to enable repeated measurements of the pH in the bronchus mucosa. In 8 conditioned mongrel dogs (20-25 kg) an autotransplant of a 4-ring segment of the thoracic trachea was performed and wrapped with an omental pedicle flap in 4 of them (omentum group vs control group). PH-measurements of the mucosa were performed at 3 points of the circumference of the normal trachea as well as the transplant. The measurements were done immediately postoperative and at day 3, 8, 14 and 20 using a modified MI 506 pH-needle electrode with an Ag-AgCl skin reference electrode and a Fisher accumet pH-meter (model 910). After 3 weeks or at occurrence of a severe tracheal stenosis macroscopic and histologic examination of the trachea was done. All animals in the omentum group finished the study. One developed severe stenosis due to tracheal malacia. Three of the four control-dogs had a severe tracheal stenosis at day 12, 13 and 16 which necessitated termination of the experiment. The pH-difference between trachea and transplant immediately postoperative was 0.16 +/- 0.02 in the 4 dogs with healed transplants and 0.15 + 0.03 in the 4 dogs with stenosis due to chondromalacia. Follow-up measurements at day 3 and 8 showed a pH-difference of 0.2 for the group with chondromalacia vs. 0.1 for the healed tracheas (not significant).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

气道缺血是肺移植严重并发症的主要原因。组织pH值被用作心肌及其他各种组织缺血的指标。我们研发了一种pH针式探头,可通过支气管镜应用,以便对支气管黏膜的pH值进行重复测量。在8只条件适宜的杂种犬(体重20 - 25千克)身上,对胸段气管的4环节段进行自体移植,其中4只犬用网膜蒂瓣包裹(网膜组与对照组)。在正常气管以及移植气管的圆周3个点处进行黏膜pH测量。术后即刻以及术后第3、8、14和20天,使用带有Ag - AgCl皮肤参比电极的改良MI 506 pH针式电极和Fisher Accumet pH计(910型)进行测量。3周后或出现严重气管狭窄时,对气管进行大体和组织学检查。网膜组所有动物均完成研究。1只因气管软化出现严重狭窄。4只对照犬中有3只在第12、13和16天出现严重气管狭窄,致使实验终止。移植成功愈合的4只犬术后即刻气管与移植气管之间的pH差值为0.16±0.02,因软骨软化出现狭窄的4只犬为0.15 + 0.03。第3天和第8天的随访测量显示,软骨软化组的pH差值为0.2,愈合气管组为0.1(无显著性差异)。(摘要截取自250词)

相似文献

7
Tracheal autograft revascularization.
J Thorac Cardiovasc Surg. 1987 Sep;94(3):434-41.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验