Stevens Richard C, Soelberg Scott D, Near Steve, Furlong Clement E
Department of Medicine, Division of Medical Genetics, University of Washington, Seattle, Washington 98195, USA.
Anal Chem. 2008 Sep 1;80(17):6747-51. doi: 10.1021/ac800892h. Epub 2008 Jul 26.
Saliva provides a useful and noninvasive alternative to blood for many biomedical diagnostic assays. The level of the hormone cortisol in blood and saliva is related to the level of stress. We present here the development of a portable surface plasmon resonance (SPR) biosensor system for detection of cortisol in saliva. Cortisol-specific monoclonal antibodies were used to develop a competition assay with a six-channel portable SPR biosensor designed in our laboratory. The detection limit of cortisol in laboratory buffers was 0.36 ng/mL (1.0 nM). An in-line filter based on diffusion through a hollow fiber hydrophilic membrane served to separate small molecules from the complex macromolecular matrix of saliva prior to introduction to the sensor surface. The filtering flow cell provided in-line separation of small molecules from salivary mucins and other large molecules with only a 29% reduction of signal compared with direct flow of the same concentration of analyte over the sensor surface. A standard curve for detection of cortisol in saliva was generated with a detection limit of 1.0 ng/mL (3.6 nM), sufficiently sensitive for clinical use. The system will also be useful for a wide range of applications where small molecular weight analytes are found in complex matrixes.
对于许多生物医学诊断分析而言,唾液为血液提供了一种有用且非侵入性的替代物。血液和唾液中激素皮质醇的水平与压力水平相关。我们在此展示了一种用于检测唾液中皮质醇的便携式表面等离子体共振(SPR)生物传感器系统的研发情况。使用皮质醇特异性单克隆抗体,与我们实验室设计的六通道便携式SPR生物传感器开展了一项竞争分析。在实验室缓冲液中,皮质醇的检测限为0.36 ng/mL(1.0 nM)。基于通过中空纤维亲水膜扩散的在线过滤器,用于在将唾液引入传感器表面之前,从小分子唾液复杂的大分子基质中分离出小分子。与相同浓度分析物直接流过传感器表面相比,过滤流通池能从小分子唾液粘蛋白和其他大分子中在线分离出小分子,且信号仅降低29%。生成了唾液中皮质醇检测的标准曲线,检测限为1.0 ng/mL(3.6 nM),对临床应用而言灵敏度足够。该系统对于在复杂基质中发现小分子重量分析物的广泛应用也将是有用的。