Suppr超能文献

脉搏血氧饱和度指数:一种用于静脉疾病患者的简单动脉评估方法。

Pulse oximetry index: a simple arterial assessment for patients with venous disease.

作者信息

Bianchi J, Zamiri M, Loney M, McIntosh H, Dawe R S, Douglas W S

机构信息

Glasgow Caledonian University, Scotland, UK.

出版信息

J Wound Care. 2008 Jun;17(6):253-4, 256-8, 260. doi: 10.12968/jowc.2008.17.6.29585.

Abstract

OBJECTIVE

To provide additional safety data comparing ankle brachial pressure index (ABPI) and pulse oximetry (Lanarkshire Oximetry Index, LOI) as measures of arterial circulation in patients with venous disease of the leg.

METHOD

A total of 107 (195 legs) attending hospital leg ulcer clinics participated in this prospective open study. We attempted to measure brachial and foot arterial pressures in all patients using both the handheld Doppler method (ABPI) and pulse oximeter method (LOI). Features of patients with limbs in which either the ABPI or LOI could not be assessed were documented. ABPI and LOI values were compared, and agreement between the two assessment methods was assessed.

RESULTS

We found the LOI measurement to be a simpler technique than Doppler ABPI measurement, with an endpoint less prone to the subjective variability associated with the Doppler method. Of the 195 legs assessed,we obtained LOI in 10 in which an ABPI could not be recorded. LOI could not be recorded in only one leg. There was a linear association (p<0.001) and fair agreement (kappa=0.303) between LOI and ABPI in the 184 legs in which both ratios could be measured. There was no evident tendency for LOI to read either low or high compared with ABPI.

CONCLUSION

Pulse oximetry LOI is a simple alternative to Doppler ABPI in the screening of patients for arterial disease that could be a contraindication to, or require modification of, compression therapy. It can be measured in some legs that cannot be assessed by Doppler ultrasound.

摘要

目的

比较踝肱压力指数(ABPI)和脉搏血氧饱和度测定法(拉纳克郡血氧饱和度指数,LOI)作为腿部静脉疾病患者动脉循环测量指标时的额外安全性数据。

方法

共有107名(195条腿)前往医院腿部溃疡门诊的患者参与了这项前瞻性开放性研究。我们尝试使用手持式多普勒方法(ABPI)和脉搏血氧仪方法(LOI)测量所有患者的肱动脉和足部动脉压力。记录了无法评估ABPI或LOI的肢体患者的特征。比较了ABPI和LOI值,并评估了两种评估方法之间的一致性。

结果

我们发现LOI测量是一种比多普勒ABPI测量更简单的技术,其终点不太容易出现与多普勒方法相关的主观变异性。在评估的195条腿中,我们在10条腿上获得了LOI,而这些腿无法记录ABPI。仅在1条腿上无法记录LOI。在184条可以测量两种比率的腿中,LOI与ABPI之间存在线性关联(p<0.001)和中等一致性(kappa=0.303)。与ABPI相比,LOI没有明显的读值偏低或偏高的趋势。

结论

脉搏血氧饱和度测定法LOI是多普勒ABPI的一种简单替代方法,可用于筛查可能是压迫治疗的禁忌症或需要对压迫治疗进行调整情况的动脉疾病患者。它可以在一些无法通过多普勒超声评估的腿部进行测量。