Garg Amit K, Frija Erik K, Sun Tzouh-Liang, Strom Eric A, Perkins George H, Oh Julia L, Yu Tsu-Kuan, Woodward Wendy A, Tereffe Welella A, Salehpour Mohammad, Buchholz Thomas A
Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX, USA.
Int J Radiat Oncol Biol Phys. 2009 Feb 1;73(2):370-4. doi: 10.1016/j.ijrobp.2008.04.045.
To determine the differences in dosimetric coverage of the Level III axillary node target as a function of the superior tangential/supraclavicular match line in breast cancer patients undergoing with tangential breast and supraclavicular fossa radiotherapy.
The data from 20 consecutive breast cancer patients who were treated with breast conservation surgery and Level I and II axillary dissection followed by radiotherapy to the undissected Level III axilla/supraclavicular fossa were retrospectively analyzed. The nodal volumes were delineated from the computed tomography simulation data set. Three composite treatment plans were generated for each patient according to the placement of the match line.
Coverage of the contoured Level III/axillary apex varied significantly with respect to the ipsilateral clavicular head, depending on the placement of the superior tangential/supraclavicular match line. The mean volume of the Level III/axillary apex covered by the 90% isodose line (45 Gy) was 100% for caudal placement of the match line, significantly greater than the 92% for intermediate placement (bisecting the clavicular head; p = 0.001) and the 68% for cranial placement with respect to the clavicular head (p < 0.001).
Placement of the superior tangential/supraclavicular match line caudal to the clavicular head results in statistically improved dosimetric coverage of the Level III axilla/axillary apex in breast cancer patients undergoing tangential/supraclavicular radiotherapy.
确定在接受乳腺切线野和锁骨上窝放疗的乳腺癌患者中,III级腋窝淋巴结靶区剂量覆盖情况随上切线/锁骨上匹配线位置变化的差异。
回顾性分析20例连续乳腺癌患者的数据,这些患者接受了保乳手术及I级和II级腋窝淋巴结清扫,随后对未清扫的III级腋窝/锁骨上窝进行放疗。根据计算机断层扫描模拟数据集勾勒出淋巴结体积。根据匹配线的位置为每位患者生成三个综合治疗计划。
根据上切线/锁骨上匹配线的位置,III级/腋窝尖部的轮廓覆盖范围相对于同侧锁骨头部有显著差异。匹配线下位放置时,90%等剂量线(45 Gy)覆盖的III级/腋窝尖部平均体积为100%,显著大于匹配线中位放置(平分锁骨头部)时的92%(p = 0.001)以及匹配线上位放置时相对于锁骨头部的68%(p < 0.001)。
在上切线/锁骨上匹配线置于锁骨头部下方时,接受切线野/锁骨上放疗的乳腺癌患者III级腋窝/腋窝尖部的剂量覆盖在统计学上有改善。