Suppr超能文献

冠状动脉支架的多排螺旋CT血管造影术进展:采用双源CT对29种不同类型支架进行体外评估

Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

作者信息

Maintz David, Burg Matthias C, Seifarth Harald, Bunck Alexander C, Ozgün Murat, Fischbach Roman, Jürgens Kai Uwe, Heindel Walter

机构信息

Department of Clinical Radiology, University of Münster, Münster, Germany.

出版信息

Eur Radiol. 2009 Jan;19(1):42-9. doi: 10.1007/s00330-008-1132-5. Epub 2008 Aug 6.

Abstract

The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54 +/- 8.3%) and most realistic lumen attenuation (222 +/- 44 HU) at the expense of increased noise (23.9 +/- 1.9 HU) compared with standard CTA protocols (p < 0.001 for all). The magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%.

摘要

本研究的目的是在体外双源多层螺旋CT(DSCT)中,使用四种图像重建方法,针对管腔可视化、管腔衰减和图像噪声,对大量最新的冠状动脉支架进行测试,并提供当前使用的冠状动脉支架的CT目录。在冠状动脉模型(血管直径3mm,血管内衰减250HU,血管外密度-70HU)中检查了29种不同的冠状动脉支架(19种钢质、6种钴铬合金、2种钽质、1种铁质、1种镁质)。支架以轴向方向成像,采用标准参数:32×0.6准直、螺距0.24、400mAs、120kV、旋转时间0.33s。使用四种不同的卷积核(软组织、中软组织、标准高分辨率、支架专用)进行图像重建。为了评估支架的可视化特征,测量了管腔直径、腔内密度和噪声。与标准CTA协议相比,支架专用核提供了最佳的平均管腔可视化(54±8.3%)和最逼真的管腔衰减(222±44HU),但代价是噪声增加(23.9±1.9HU)(所有p<0.001)。镁质支架的伪影最少,管腔可见度为90%。大多数支架(79%)的管腔可见度为50-59%。只有六种支架中不到一半的管腔可见。支架管腔可见度在很大程度上取决于支架类型。与更常见的材料钢、钴铬合金或钽相比,就CT成像而言,镁质支架是一种更有利的支架材料。镁质支架的管腔可见度为90%,而其他大多数支架的管腔可见度为50-59%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验