Heuser R R, Mehta S S
Department of Cardiology, Arizona Heart Institute, Phoenix 85064.
Cathet Cardiovasc Diagn. 1991 Jul;23(3):187-9. doi: 10.1002/ccd.1810230309.
A new solid-state laser system was used in a case of saphenous vein graft occlusion untreatable by standard very low-profile balloon angioplasty. The 2100 nm infrared pulsed thulium/holmium: YAG laser successfully recanalized an obtuse marginal bypass graft without complications. The holmium laser has several advantages over excimer systems and may prove an effective adjunct or alternative to coronary balloon angioplasty.
一种新型固态激光系统被用于一例经标准的极薄型球囊血管成形术无法治疗的隐静脉移植血管闭塞病例。2100纳米红外脉冲铥/钬:YAG激光成功地使一条钝缘支旁路移植血管再通,且无并发症。与准分子激光系统相比,钬激光有几个优点,可能证明是冠状动脉球囊血管成形术的一种有效辅助手段或替代方法。