• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Dose in bone and tissue near bone-tissue interface from electron beam.

作者信息

Shiu A S, Hogstrom K R

机构信息

Department of Radiation Physics, University of Texas M.D. Anderson Cancer Center, Houston 77030.

出版信息

Int J Radiat Oncol Biol Phys. 1991 Aug;21(3):695-702. doi: 10.1016/0360-3016(91)90688-z.

DOI:10.1016/0360-3016(91)90688-z
PMID:1869463
Abstract

This work has quantitatively studied the variation of dose both within bone and in unit density tissue near bone-tissue interfaces. Dose upstream of a bone-tissue interface is increased because of an increase in the backscattered electrons from the bone. The magnitude of this effect was measured using a thin parallel-plate ionization chamber upstream of a polymethyl methacrylate (PMMA)-hard bone interface. The electron backscatter factor (EBF) increased rapidly with bone thickness until a full EBF was achieved. This occurred at approximately 3.5 mm at 2 MeV and 6 mm at 13.1 MeV. The full EBF at the interface ranged from approximately 1.018 at 13.1 MeV to 1.05 at 2 MeV. It was also observed that the EBF had a dependence on the energy spectrum at the interface. The penetration of the backscattered electrons in the upstream direction of PMMA was also measured. The dose penetration fell off rapidly in the upstream direction of the interface. Dose enhancement to unit density tissue in bone was measured for an electron beam by placing thermoluminescent dosimeters (TLDs) in a PMMA-bone-PMMA phantom. The maximum dose enhancement in bone was approximately 7% of the maximum dose in water. However, the pencil-beam algorithm of Hogstrom et al. predicted an increase of only 1%, primarily owing to the inverse-square correction. Film was also used to measure the dose enhancement in bone. The film plane was aligned either perpendicular or parallel to the central axis of the beam. The film data indicated that the maximum dose enhancement in bone was approximately 8% for the former film alignment (which was similarly predicted by the TLD measurements) and 13% for the latter film alignment. These results confirm that the X ray film is not suitable to be irritated "edge on" in an inhomogeneous phantom without making perturbation corrections resulting from the film acting as a long narrow inhomogeneous cavity within the bone. In addition, the results give the radiotherapist a basis for clinical judgment when electron beams are used to treat lesions behind bone or near bony structures. We feel these data enhance the ability to recognize the shortcomings of the current dose calculation algorithm used clinically.

摘要

相似文献

1
Dose in bone and tissue near bone-tissue interface from electron beam.
Int J Radiat Oncol Biol Phys. 1991 Aug;21(3):695-702. doi: 10.1016/0360-3016(91)90688-z.
2
Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc.使用EGSnrc对临床电子束在铅中的反向散射进行蒙特卡罗模拟。
Med Phys. 2008 Apr;35(4):1241-50. doi: 10.1118/1.2874552.
3
Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.皮肤放射治疗中的骨和粘膜剂量学:使用千伏级光子和兆伏级电子束的蒙特卡罗研究。
Phys Med Biol. 2012 Jun 21;57(12):3885-99. doi: 10.1088/0031-9155/57/12/3885. Epub 2012 May 30.
4
Dosimetric evaluation of lead and tungsten eye shields in electron beam treatment.电子束治疗中铅和钨眼屏蔽的剂量学评估
Int J Radiat Oncol Biol Phys. 1996 Jun 1;35(3):599-604. doi: 10.1016/s0360-3016(96)80024-1.
5
Backscattering in electron beam therapy for energies between 3 and 35 MeV.3至35兆电子伏特能量范围内电子束治疗中的反向散射
Phys Med Biol. 1982 Mar;27(3):363-73. doi: 10.1088/0031-9155/27/3/003.
6
A comparison of three electron planning algorithms for a 16 MeV electron beam.16兆电子伏电子束的三种电子治疗计划算法比较。
Int J Radiat Oncol Biol Phys. 1994 Feb 1;28(3):731-40. doi: 10.1016/0360-3016(94)90201-1.
7
Dose enhancement from backscattered radiation at tissue-metal interfaces irradiated with high energy electrons.
Br J Radiol. 1980 May;53(629):466-70. doi: 10.1259/0007-1285-53-629-466.
8
The effect on dose of kilovoltage x-rays backscattered from lead.铅对千伏X射线反向散射剂量的影响。
Int J Radiat Oncol Biol Phys. 1992;24(1):171-5. doi: 10.1016/0360-3016(92)91038-o.
9
Dose enhancement in bone in electron beam therapy.
Radiology. 1984 May;151(2):513-6. doi: 10.1148/radiology.151.2.6424176.
10
Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams.电子束中平行板电离室深度相关注量扰动的蒙特卡罗研究
Med Phys. 2014 Nov;41(11):111707. doi: 10.1118/1.4897389.