The Nd: YAG contact laser technique with 12 W power output was used in partial nephrectomies in six piglets. Blood loss, total time and number of ligatures needed for haemostasis were compared in six partial nephrectomies performed with a steel scalpel. Mean blood loss was 53 g with the laser and 108 g with the steel scalpel (p less than 0.04). The mean time needed for haemostasis were 9.5 and 16.2 min respectively (p = 0.2) and the average number of ligatures required 1.5 and 8.8, respectively. The mean temperature rise at 5, 10 and 20 mm distance from the resection line was 5.3, 1.2 and 0.3 degrees C, respectively. The use of laser reduced blood loss and shortened the operation time. Further studies are needed concerning renal function after kidney surgery with a laser.
采用输出功率为12W的Nd:YAG接触式激光技术对6只仔猪进行了部分肾切除术。对使用钢手术刀进行的6例部分肾切除术的失血量、总时间和止血所需结扎线数量进行了比较。激光组平均失血量为53g,钢手术刀组为108g(p<0.04)。止血平均所需时间分别为9.5分钟和16.2分钟(p = 0.2),平均所需结扎线数量分别为1.5根和8.8根。距切除线5mm、10mm和20mm处的平均温度升高分别为5.3℃、1.2℃和0.3℃。激光的使用减少了失血量并缩短了手术时间。关于激光肾脏手术后的肾功能还需要进一步研究。