Hansen T E, Naeser K, Nilsen N E
Department of Ophthalmology, Vejle Sygehus, Denmark.
Acta Ophthalmol (Copenh). 1991 Apr;69(2):225-8. doi: 10.1111/j.1755-3768.1991.tb02715.x.
The intraocular pressure in 50 eyes of 50 patients was measured 2 1/2 years after planned extracapsular cataract extraction with intended implantation of a posterior chamber lens in the ciliary sulcus. The results were compared to the preoperative values, and the pressure observed after 4 months. Although a significant elevation was found from the fourth month (P = 0.015), the intraocular pressure at 2 1/2 years was found to be significantly lower than the preoperative value (P = 0.002). No significant difference was found in two subgroups in which transillumination defects in the iris or pigment in the lower anterior chamber angle was present.
对50例患者的50只眼睛在计划进行囊外白内障摘除并打算将后房型人工晶状体植入睫状沟2年半后测量眼压。将结果与术前值以及4个月后观察到的眼压进行比较。尽管从第4个月起眼压有显著升高(P = 0.015),但发现2年半时的眼压显著低于术前值(P = 0.002)。在存在虹膜透照缺损或前房下角色素沉着的两个亚组中未发现显著差异。