Cohen R, Foucher R, Sfaxi A, Hakim M, Domniez T, Elhadad S
Service de cardiologie, centre hospitalier Lagny-Marne-la-Vallée, 31 avenue du Général-Leclerc, Lagny-sur-Marne, France.
Ann Cardiol Angeiol (Paris). 2010 Feb;59(1):48-51. doi: 10.1016/j.ancard.2008.07.015. Epub 2008 Aug 26.
Percutaneous coronary interventions (PCI) of complex coronary lesions in patients with severely depressed left ventricular (LV) function may increasingly constitute an alternative to surgical revascularization. The availability of hemodynamic support devices offers a promising option to reduce PCI-related complications in such high-risk procedures. We report the case of a successful distal left main coronary artery T-stenting supported by the Impella Recover LP 2.5 assist device in a patient with severe LV dysfunction.
对于左心室(LV)功能严重受损的患者,复杂冠状动脉病变的经皮冠状动脉介入治疗(PCI)可能越来越多地成为外科血运重建的替代方案。血流动力学支持设备的应用为在这种高风险手术中减少PCI相关并发症提供了一个有前景的选择。我们报告了一例在严重LV功能障碍患者中,使用Impella Recover LP 2.5辅助设备成功进行左冠状动脉主干远端T型支架置入的病例。