J Orthop Sports Phys Ther. 1989;11(4):150-4. doi: 10.2519/jospt.1989.11.4.150.
The purpose of this study was to determine the intrarater and interrater reliability of mean peak torque values for the reciprocal motions of plantarflexion/dorsiflexion (PF/DF) and inversion/eversion (INV/EVER), generated isokinetically at 60 and 120 degrees /sec. Forty-one healthy subjects, ranging in age from 20-75, were tested on three different occasions. The three test sessions were performed at the same time of day and separated by at least 24 hours. Pearson product-moment correlations were used to determine reliability for all ankle motions tested. Intrarater reliability of peak torque values for PF/DF and INV/EVER at both speeds ranged from 0.78-0.94, while the range of interrater coefficients was from 0.82-0.94. The results of this study suggest that when using a well defined clinical protocol, acceptable reliability for both test-retest and interrater situations can be obtained for isokinetic peak torque values of the ankle musculature at low and relatively high test speeds. J Orthop Sports Phys Ther 1989;11(4):150-154.
本研究旨在确定在 60 和 120 度/秒的等速条件下,对足背屈/跖屈(PF/DF)和内翻/外翻(INV/EVER)进行往复运动时,平均峰值扭矩值的组内和组间可靠性。41 名健康受试者,年龄在 20-75 岁之间,在三种不同情况下进行了测试。三次测试均在同一天的同一时间进行,间隔至少 24 小时。使用皮尔逊积矩相关系数来确定所有测试踝关节运动的可靠性。在两种速度下,PF/DF 和 INV/EVER 的峰值扭矩值的组内可靠性范围为 0.78-0.94,而组间系数范围为 0.82-0.94。本研究结果表明,当使用明确的临床方案时,在低测试速度和相对高测试速度下,踝关节肌肉的等速峰值扭矩值的测试-重测和组间情况都可以获得可接受的可靠性。J Orthop Sports Phys Ther 1989;11(4):150-154.