Multi-increment sampling (MIS) has been most extensively used for munitions constituents at environmental sites where a high degree of contaminant heterogeneity exits. A revised method (USEPA Method 8330B) for explosives that uses MIS was announced in the fall of 2006, but similar guidance has not been reported for testing metals in soils. Questions have been raised as how to prepare representative analytical samples for metals determination from field composites. Three different grinding procedures were used in this study for three soil types to determine if grinding (relative to homogenizing soil without grinding) increases metal concentrations and decreases variability. The performance of these procedures was demonstrated via the analysis of replicates (n=16 for two soil types) using statistical evaluations that included calculations of various descriptive statistics (e.g., medians, means and standard deviations), Kruskal-Wallis (KW) tests for the medians and two tests for the variances (Bartlett's and Levene's test). There was a slight increase in concentrations for several of the metals in the clay loam soil after grinding, although the increases were a small percentage of the concentrations measured. The standard deviations (and variances) for replicate digestions and analyses generally decreased, although anomalies were observed. The grinding methods increased precision overall, however, the data indicated that the roller mill grinding was not as effective as the other grinding methods tested.
多增量采样(MIS)在污染物高度异质性存在的环境场地中,已被最广泛地用于弹药成分分析。2006年秋季公布了一种使用MIS的爆炸物修订方法(美国环保署方法8330B),但尚未有针对土壤中金属检测的类似指南报道。对于如何从现场混合样中制备用于金属测定的代表性分析样品,人们提出了疑问。本研究针对三种土壤类型使用了三种不同的研磨程序,以确定研磨(相对于不研磨直接均质化土壤)是否会增加金属浓度并降低变异性。通过对重复样品(两种土壤类型各n = 16)进行分析,并使用包括计算各种描述性统计量(如中位数、均值和标准差)、中位数的Kruskal-Wallis(KW)检验以及两种方差检验(Bartlett检验和Levene检验)的统计评估,来证明这些程序的性能。研磨后,粘壤土中几种金属的浓度略有增加,尽管增加量仅占所测浓度的一小部分。重复消解和分析的标准差(和方差)总体上有所降低,不过也观察到了异常情况。总体而言,研磨方法提高了精密度,然而,数据表明辊磨机研磨不如所测试的其他研磨方法有效。