Tuthill T A, Baggs R B, Violante M R, Parker K J
Department of Electrical Engineering, University of Rochester, NY 14627.
Ultrasound Med Biol. 1991;17(3):231-7. doi: 10.1016/0301-5629(91)90044-w.
Basic acoustic parameters are examined in rabbit liver with and without a solid contrast agent used for tumor detection. In normal liver, backscatter, attenuation, and sound speed are found to decrease with increasing water content. The addition of micron-sized particles made from iodipamide ethyl ester (IDE) can increase backscatter and attenuation depending on size and concentration. A discrepancy of the increased backscatter from theoretical predictions based on random scatterers is attributed to the particle's biodistribution in the liver.
在有和没有用于肿瘤检测的固体造影剂的情况下,对兔肝的基本声学参数进行了检查。在正常肝脏中,发现背向散射、衰减和声速会随着含水量的增加而降低。添加由碘番酸乙酯(IDE)制成的微米级颗粒可根据尺寸和浓度增加背向散射和衰减。与基于随机散射体的理论预测相比,背向散射增加存在差异,这归因于颗粒在肝脏中的生物分布。