• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Effect of lung hyperinflation and endotracheal suctioning on heart rate and rhythm in patients after coronary artery bypass graft surgery.

作者信息

Stone K S, Talaganis S A, Preusser B, Gonyon D S

机构信息

College of Nursing, Ohio State University, Columbus 43210-1289.

出版信息

Heart Lung. 1991 Sep;20(5 Pt 1):443-50.

PMID:1894523
Abstract

We examined the effect of lung hyperinflation and suction on PaO2, heart rate, and rhythm in patients after coronary artery bypass graft surgery (N = 26). Three lung hyperinflation breaths, at one of five randomly ordered volumes (tidal volume, 12 cc/kg, 14 cc/kg, 16 cc/kg, or 18 cc/kg of lean body weight) were delivered, by a ventilator (fraction of inspired oxygen 1.0), followed by 10 seconds of continuous suction. Lung hyperinflation and suctioning were repeated three times. Repeated-measures analysis of variance revealed a statistically significant increase (p = 0.000) in PaO2 immediately after the third suction pass, which was volume dependent (p = 0.009). A statistically significant (p less than 0.001) increase in heart rate from baseline occurred over the three lung hyperinflation-suctioning sequences that was not volume dependent. The mean increase in heart rate was 6.8 beats/min. The majority of rhythm changes for lung hyperinflation and suctioning were from normal sinus rhythm to sinus tachycardia. Suction was associated with a greater incidence of rhythm (53.9%) and arrhythmia (80.8%) changes. The most frequent arrhythmia was premature atrial contraction.

摘要

相似文献

1
Effect of lung hyperinflation and endotracheal suctioning on heart rate and rhythm in patients after coronary artery bypass graft surgery.
Heart Lung. 1991 Sep;20(5 Pt 1):443-50.
2
The effect of lung hyperinflation and endotracheal suctioning on cardiopulmonary hemodynamics.肺过度充气和气管内吸痰对心肺血流动力学的影响。
Nurs Res. 1991 Mar-Apr;40(2):76-80.
3
Effect of oxygen insufflation during endotracheal suctioning on arterial pressure and oxygenation in coronary artery bypass graft patients.冠状动脉搭桥术患者气管内吸痰时吹氧对动脉压和氧合的影响
Am J Crit Care. 1994 May;3(3):191-7.
4
Effectiveness of oxygen concentrations of less than 100% before and after endotracheal suction in patients with chronic obstructive pulmonary disease.
Heart Lung. 1989 Jan;18(1):64-71.
5
Arterial blood gas changes with a hyperinflation and hyperoxygenation suctioning intervention in critically ill patients.危重症患者高通气和高氧吸痰干预后的动脉血气变化
Heart Lung. 1988 Nov;17(6 Pt 1):654-61.
6
Effects of lung hyperinflation on mean arterial pressure and postsuctioning hypoxemia.肺过度充气对平均动脉压和吸痰后低氧血症的影响。
Heart Lung. 1989 Jul;18(4):377-85.
7
Efficacy of a hyperinflation and hyperoxygenation suctioning intervention.
Heart Lung. 1988 Jan;17(1):15-22.
8
Endotracheal suctioning: ventilator vs manual delivery of hyperoxygenation breaths.气管内吸痰:呼吸机与手动给予高氧通气的比较。
Am J Crit Care. 1996 May;5(3):192-7.
9
Nurses' ability to achieve hyperinflation and hyperoxygenation with a manual resuscitation bag during endotracheal suctioning.护士在气管内吸痰期间使用手动复苏袋实现肺过度充气和高氧通气的能力。
Heart Lung. 1993 Mar-Apr;22(2):158-65.
10
[The effects of endotracheal suction on gas exchange and respiratory mechanics in mechanically ventilated patients under pressure-controlled or volume-controlled ventilation].[气管内吸引对压力控制或容量控制通气下机械通气患者气体交换和呼吸力学的影响]
Zhonghua Jie He He Hu Xi Za Zhi. 2007 Oct;30(10):751-5.

引用本文的文献

1
Endotracheal suctioning versus minimally invasive airway suctioning in intubated patients: a prospective randomised controlled trial.气管内吸痰与微创气道吸痰用于插管患者的比较:一项前瞻性随机对照试验。
Intensive Care Med. 2003 Mar;29(3):426-32. doi: 10.1007/s00134-003-1639-9. Epub 2003 Feb 8.